FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
I cannot convert a circuit created with GX Developer.
When the conversion is executed, online change is automatically executed.When the online change at the upper right section of the setting in "Options" of "To... More Details >>
- No:22958
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
Terminating resistors for RS-485 communication of LJ71C24
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22999
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:25
- Category: Network related products
-
Order in which a CC-Link master module and slave stations are connected
There is no restriction on the positions of a master station and slave stations where they are connected. (Stations are not required to be connected in order... More Details >>
- No:23041
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Error 2035 (Command frequency error) occurs when the servo amplifier detects a command frequency error. (1) When the command from the controller is the permi... More Details >>
-
It depends on the setting of servo parameter "[PA03] Absolute position detection system" whether the HPR request flag ("[Md.31] Status": b3) turns ON or not.... More Details >>
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Assignment of input/output numbers (MELSEC-F series)
Octal numbers are assigned as input/output numbers for the MELSEC-F series. The octal number system uses the digits from 0 to 7 → from 10 to 17 → from 20 to... More Details >>
- No:24868
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Storage media of a project file
The project file written in the write-inhibited media, such as FD, CD-R, or CD-RW, cannot be read. (Condition: The standard Windows status without CD-R/RW w... More Details >>
- No:25007
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Engineering Software
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Turning on a bit in the data register
In the FX3U/FX3UC series, the bit specification of the data register is possible. (Example) D0.7→7th bit in D0 For the other types of MELSEC-F programmable... More Details >>
- No:22275
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
651-660 of Total 1110