FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
You can use the MELSEC iQ-R series inter-module synchronization function together with the CC-Link IE Field Network synchronous communication function.With ... More Details >>
- No:22462
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:51
- Category: MELSEC iQ-R Series
-
A password can be set. - Use the file password 32 function.- Number of characters: 4 to 32 (alphanumeric and special characters, case-sensitive)- Disabled op... More Details >>
- No:22810
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
MX Component Version 4's compatibility with Visual C++ .NET 2003
MX Component Version 4 does not support Visual C++ .NET 2003. More Details >>
- No:22874
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Error 3012 occurs when the multiple CPU setting of PLC CPU (CPU No.1) does not match that of Motion CPU. (1) Check if the multiple CPU setting of the Multipl... More Details >>
-
Unable to communicate via USB connection
Check the following points.(1) Transfer Setup is properly configured.(2) The USB driver is properly recognized. More Details >>
- No:22511
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
CPU clock setting by SNTP functions via built-in Ethernet port in LCPU
The clock setting of the CPU module is set automatically in accordance with the clock data collected from the time information server (SNTP server) on the LAN. More Details >>
- No:22736
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Execution of the SOCRMODE instruction in the same connection during socket communication of LCPU
It can be executed for the same connection number. When data exist in the socket communication receive data area and the SOCRMODE instruction is executed, va... More Details >>
- No:22771
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Compatibility between MX Component Version 3 and 4
Applications created using MX Component Version 3 can be used, as they are, on a personal computer on which MX Component Version 4 is installed. MX Component... More Details >>
- No:22839
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Cause to turn on the ERR LED of a CC-Link master module
All stations communication error of a slave station.When POWER of the slave station is off, check if 24 V DC has been supplied.When POWER is on, check the st... More Details >>
- No:23079
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Versions of LCPU compatible with LJ71E71-100
The L series CPU serial numbers with upper 5 digits of "14112" or later indicate compatibility with LJ71E71-100. More Details >>
- No:22770
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
651-660 of Total 1123