FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Input of the R device of the FX3U series in the FX-20P
Since the FX3U series does not support the FX-20P, available device ranges are within the range of the FX2N. ("R" devices do not exist in the FX2N.) The ha... More Details >>
- No:24989
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Accessories
-
Temperature input modules that can be used with FX3G series
FX3U-4AD-PT-ADP (Pt100 temperature sensor input special adapter), FX3U-4AD-PTW-ADP (Pt100 temperature sensor input special adapter), and FX3U-4AD-TC-ADP (K/J... More Details >>
- No:24993
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Analog Control
-
Remote maintenance can be performed by writing a program to a memory cassette and sending the program or by using a personal computer (GX Developer). With a ... More Details >>
- No:24998
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Main Unit
-
The FX2N-16CCL-M cannot be set as the master station in the parameter setting. Use the FROM/TO instructions and setin the program. More Details >>
- No:25001
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Network/Communication
-
FX series products that support CC-Link Ver.2.0
FX3U-16CCL-M CC-Link master block and the FX3U-64CCL CC-Link interface block supports CC-Link Ver.2.0. Both blocks are dedicated for the FX3 series. More Details >>
- No:25004
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Network/Communication
-
Reflecting the changes in the communication setting
Power off and on the programmable controller again after the communication setting is changed. More Details >>
- No:25006
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Connection of a totem pole output encoder
The totem pole output encoder cannot be connected to the FX2NC-1HC/FX2N-1HC/ FX3U-2HC. The connectable encoders are as follows. ・ Open collector output typ... More Details >>
- No:25010
- Release Date:2019/04/23 11:12
- Category: MELSEC-F Series , High-Speed Counting
-
The FX5 CPU module does not support CAN communication. More Details >>
- No:39286
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding firmware updates for newly purchased CPU modules
You can still update the firmware. More Details >>
- No:39300
- Release Date:2023/02/13 16:40
- Category: MELSEC iQ-F Series , CPU Module
701-710 of Total 1082