The setting in Latch (1) can be cleared by latch clear operation. The setting in Latch (2) cannot be cleared by latch clear operation. More Details >>
- No:22567
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:48
- Category: MELSEC-Q Series
-
Ethernet communication after the replacement of an external device
Personal computers have different MAC addresses and an Ethernet module hold a MAC address. Hence the MAC address that the Ethernet module currently holds is ... More Details >>
- No:22665
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Remedy for the division-related operation error
The operation error occurs when the divisor is 0.Create a program in which a comparison operation instruction or another method executes a division instructi... More Details >>
- No:22691
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Number of points used for I/O assignment of L26CPU-(P)BT built-in CC-Link function
It is fixed to 32 points from 10 to 2F. More Details >>
- No:22777
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The minimum input response times are different. The minimum input response time is 100 microseconds for standard inputs, and 10 microseconds for high-speed i... More Details >>
- No:22804
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
T-branch connection and star topology for CC-Link networks
- T-branch T-branch is a connection type that branches one line from a main line. To establish a T-branch CC-Link network, use the repeater module AJ65S... More Details >>
- No:23024
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:00
- Category: Network related products
-
Operation speed change during a positioning operation of the FX3U-1PG
Yes, it is possible. Write a new value to the operation speed change value (BFM#56, #55) during the positioning operation. * After the operation speed chang... More Details >>
- No:24927
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Positioning Control
-
Operation processing time of the programmable controller
The constant operation processing time can be achieved by using constant scan mode. Refer to the programming manual of the programmable controller used. More Details >>
- No:24997
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding analog ADP Power Supply abnormalities
H3081 is caused by an analog ADP power failure and the analog ADP is not receiving power normally. The FX5-4A-ADP and FX5-4DA-ADP are adapters that require p... More Details >>
- No:44346
- Release Date:2024/03/27 15:27
- Category: MELSEC iQ-F Series , Analog
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
- Category: MELSEC iQ-F Series , Network/Communication