FAQ
FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Receiving back (echoing back) the same data sent from QJ71C24N
When data is sent from the RS-422/485 interface through RS-485 (2-wire type) communication and the same data comes back to RDA or RDB, we call it echo back. ... More Details >>
- No:23000
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:44
- Category: Network related products
-
How to set CC-Link reserved stations
- If the Network Parameter is used Make "Station Information Setting". - If the parameter is set using a dedicated instruction Set the control data of... More Details >>
- No:22996
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:41
- Category: Network related products
-
Ethernet cables for the CC-Link IE Field Network
General-purpose Ethernet cables that meet the 1000BASE-T standard (category 5e or higher) can be used. We recommend double shielded cables. Recommended pro... More Details >>
- No:22989
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:47
- Category: Network related products
-
Difference between the CC-Link IE Controller Network and a MELSECNET/H network
The CC-Link IE Controller Network is an improved system that has a higher processing speed and a larger data capacity than the MELSECNET/H network system (PL... More Details >>
- No:22979
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:17
- Category: Network related products
-
Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24
- Category: Network related products
-
Terminating resistors for RS-422 communication of QJ71C24N
The resistance value is 330 ohm, 1/4 W. More Details >>
- No:22965
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:33
- Category: Network related products
-
Can I open a program created with GX Works2 in GX Developer?
You cannot open a program in the file format for GX Works2. When saving a project with GX Works2, save it in the format for GX Developer.(This is possible on... More Details >>
- No:22956
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
I cannot open a project file of PX Developer.
When the total number of characters in the drive/path and project name exceeds 149 one-byte characters (74 two-byte characters), the message "The drive path ... More Details >>
- No:22947
- Release Date:2018/09/03 17:30
- Update:2018/09/25 10:58
- Category: Engineering Software
-
Setting for sequentially inputting device comments in GX Works2
Select [Tool]-> [Options]-> [Program Editor] -> [Ladder/SFC] -> [Enter ladder] from the menu, and set [Enter label comment and device comment]... More Details >>
- No:22938
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:54
- Category: Engineering Software
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
- Category: Engineering Software