Regarding the communication execution status output device for ADPRW instructions
It does not turn OFF automatically. Use the RST command in the program to turn it OFF. More Details >>
- No:39349
- Release Date:2023/02/15 10:07
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding changing the current address (user unit, pulse unit)
It can be changed. It is now possible to write to the address (user unit, pulse unit) by the DHCMOV command. However, writing is disabled during positioning... More Details >>
- No:39356
- Release Date:2023/02/15 13:03
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding the difference of current address (user unit, pulse unit)
The difference between the current address (user unit) and the current address (pulse unit) is as follows: The current address (user unit) becomes the unit ... More Details >>
- No:39357
- Release Date:2023/02/15 13:05
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding how to start positioning
In the case of positioning control and OPR control, there are three ways to start positioning: (1)[cd. 184] Turn on the positioning start signal. (2)Exec... More Details >>
- No:39360
- Release Date:2023/01/12 17:19
- Category: MELSEC iQ-F Series , Motion/Positioning
-
Regarding the parallel link function between CPU modules
Parallel linking between FX5 and FX3 CPU modules is not available. The N:N Network function supports communication between the FX5 CPU module and the FX3 CPU... More Details >>
- No:39364
- Release Date:2023/02/15 13:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding Device Memory Export/Import
Imports are not supported. Only exports are supported. More Details >>
- No:40027
- Release Date:2023/08/24 14:38
- Category: MELSEC iQ-F Series , Engineering Software
-
Regarding CC-Link IE Filed Basic Protocol Mixing
It is possible to mix CC-Link IE Filed Basic and general-purpose Ethernet communication. More Details >>
- No:40031
- Release Date:2023/08/24 14:40
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding analog volume support
With the FX5 CPU module , there is no CPU module or option that supports analog volumes. More Details >>
- No:40044
- Release Date:2023/08/24 16:13
- Category: MELSEC iQ-F Series , Option , CPU Module
-
Regarding the MQTT Communication Function Publish Program
You can't program it with the ladder program alone. To use the MQTT communication and email functions, you must use the module FB and program it. More Details >>
- No:40051
- Release Date:2023/08/25 11:48
- Category: MELSEC iQ-F Series , Network/Communication