Regarding number of input/output points when adding safety extension module
It will. It is treated the same as an intelligent module, so it occupies 8 I/O points. The safety input expansion module FX5-SF-8DI4 does not occupy the numb... More Details >>
- No:39314
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , CPU Module , Safety Control
-
Regarding using the FX5S CPU module Data Logging Function
SD Memory Card module: You will need an FX5-SDCD and an SD memory card. More Details >>
- No:39333
- Release Date:2023/02/14 09:09
- Category: MELSEC iQ-F Series , Option , CPU Module
-
Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding Free Mail Service with Email Function
Free mail services that have been verified to work with the email function are Gmail, Yahoo! mail, and iCloud email.(As of July 2025) Use the encryption fun... More Details >>
- No:40058
- Release Date:2023/08/25 10:22
- Update:2025/11/11 14:31
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding analog ADP Power Supply abnormalities
H3081 is caused by an analog ADP power failure and the analog ADP is not receiving power normally. The FX5-4A-ADP and FX5-4DA-ADP are adapters that require p... More Details >>
- No:44346
- Release Date:2024/03/27 15:27
- Category: MELSEC iQ-F Series , Analog
-
Types of Batteries used in MELSEC-F
F2-40BL: Lithium thionyl chloride primary battery FX2NC-32BL: Lithium thionyl chloride primary battery FX3U-32BL: Manganese dioxide lithium primary battery F... More Details >>
- No:22265
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
The power supply lamp of a running programmable controller suddenly turned off or flashes
Check whether the lamp is back to normalafter disconnecting the wiring of the "24V" (service power supply) terminal. Ifthe lamp is back to normal,the servic... More Details >>
- No:22267
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:53
- Category: MELSEC-F Series , Main Unit
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Interrupt program priority setting of MELSEC iQ-R series
You can set interrupt priorities 5 to 7 for interrupt pointers (I0 to I15, I50 to I1023) from the module. You cannot change the priorities of interrupt poin... More Details >>
- No:22482
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:05
- Category: MELSEC iQ-R Series