Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Inputting device comments in GX Works2
Select [Tool] -> [Options] -> [Program Editor] -> "Ladder/SFC"-> "Comment" and change "Reference/Reflection Target for Device Comment" from "Glob... More Details >>
- No:22559
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Is the version of MX Component compatible with Windows 7? Update the software to the version compatible with Windows 7 and then update the driver. For the ... More Details >>
- No:22569
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:50
- Category: MELSEC-Q Series
-
How to display local comments in GX Works2
In the "Reference/Reflection Target for Device Comment" window, switch the "Specify the Reference/Reflection" from "Global" to "Local". More Details >>
- No:22630
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Causes to why SD1286 does not turn on during socket communication of LCPU
Check the following. - Whether the external device specifies the port number of the corresponding connection to the L series CPU. - In the TCP fixed-length... More Details >>
- No:22787
- Release Date:2018/09/03 17:30
- Update:2018/09/22 11:51
- Category: MELSEC-L Series
-
How to use LCPU connector terminals
The LCPU connector terminals can be used as terminals for built-in I/O function. The setting of the built-in I/O function can be configured with the paramete... More Details >>
- No:22796
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Required setting for the display of hidden comments
Device comments can be displayed in the ladder editor and Zoom editor windows. Select [View] -> [Comment] from the menu to display the comments. More Details >>
- No:22875
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:40
- Category: Engineering Software
-
Connecting terminating resistors for CC-Link communication
Connect terminating resistors to both ends of physical cables.A master station is not necessarily required to be connected to either end of its network. More Details >>
- No:23046
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Connecting AJ65BT-R2N to a GOT
Yes.When connecting a GOT, set the mode setting switch of AJ65BT-R2N to "5" (MELSOFT connection mode). More Details >>
- No:23047
- Release Date:2018/09/03 17:31
- Category: Network related products
-
To assure 32-bit data, "Network Range Assignment" of the control station must satisfy the following conditions.(1) The start device No. of LB is a multiple o... More Details >>
- No:23052
- Release Date:2018/09/03 17:31
- Category: Network related products