FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Settings required for transient transmission
The routing parameter settings are required for transient transmission to the CPU module with another network No. The request source station, relay station,... More Details >>
- No:22995
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:40
- Category: Network related products
-
Overall cable distance and station-to-station distance in CC-Link networks
The overall cable distance and station-to-station distance depend on the version and the transmission speed. Figure 1 shows the case with Ver.1.10-compatibl... More Details >>
- No:23028
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:14
- Category: Network related products
-
Parameter setting of CC-Link IE Field Network
No, you do not have to set the network range assignment parameters for slave stations. By setting the network range assignment parameters for a master statio... More Details >>
- No:23066
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Regarding number of internal Ethernet port connections
The Ethernet port (P2) has 32 connections. The breakdown is as follows: total of MELSOFT connections, SLMP, and socket communications ≦ 32 connections. Apa... More Details >>
- No:44974
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding features of EtherNet/IP Communication
Class1 communication sends and receives data at regular intervals. It is mainly used for I/O communication and motion control between PLC and sensor. Class... More Details >>
- No:45485
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Maximum apparent power of the power supplies of Q00JCPU and Q00UJCPU
Both are 105 VA. More Details >>
- No:22538
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Battery replacement for universal model QCPU
The contents of the standard RAM and latch devices are not erased if the battery replacement is completed within three minutes, which is the backup power tim... More Details >>
- No:22558
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
It includes sample comments for special relay/special register and the intelligent function module. On the menu of GX Works2, select [Edit] -> [Import ... More Details >>
- No:22581
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:12
- Category: MELSEC-Q Series
-
Behavior of sequence program in event of momentary power failure in QCPU
(1) When a momentary power failure occurs for a period not longer than the allowable momentary power failure time When the momentary power failure occurs, t... More Details >>
- No:22587
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:41
- Category: MELSEC-Q Series