I/O assignment of PLC parameters with GX Works3
"PC Parameter" in GX Works2 is "Parameter" in GX Works3. You can set the I/O assignment from "Module Configuration" or "System Parameter". <Setting fr... More Details >>
- No:22475
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:42
- Category: MELSEC iQ-R Series
-
File registers "R" use the block switching method. The number of file register points used are divided and specified in units of 32k points. When multiple ... More Details >>
- No:22512
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:29
- Category: MELSEC-Q Series
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors. (1) The module that has been specified by a FROM/TO i... More Details >>
- No:22662
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:48
- Category: MELSEC-Q Series
-
Built-in variable analog potentiometers of the FX3G series
D8030 for VR1, and D8031 for VR2. More Details >>
- No:24769
- Release Date:2019/02/27 15:01
- Category: MELSEC-F Series , Main Unit , Analog Control
-
When a personal computer (GX Works2) is connected to the RS-232C port of a programmable controller, communications between the personal computer and the prog... More Details >>
- No:24782
- Release Date:2019/02/27 16:10
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>
- No:23551
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
Assignment of direction signals during positioning
Any number can be assigned. More Details >>
- No:24975
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Positioning Control
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding protocol creation of Predefined Protocol Support Function
You can not create a protocol for the other device. More Details >>
- No:39293
- Release Date:2023/02/13 15:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication