Regarding setting the FX5 CPU Module that does not support the simple CPU communication function
When connecting 2 FX5 CPU Modules (firmware version 1.110 or later) that support the Simple CPU communication function and 2 FX5 CPU Modules (firmware vers... More Details >>
- No:44329
- Release Date:2024/03/20 13:35
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding built-in ethernet port differences
Port 1 becomes the CC-Link IE TSN, and port 2 can be switched between Ethernet and CC-Link IE TSN. To use port 2 as an Ethernet port, set the Built-in Netwo... More Details >>
- No:44969
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model
-
Meanings of the sink input/source input
The sink input connects to a negative common for 24 V DC. The source input connects to a positive common. The sink input is generally used in Japan and No... More Details >>
- No:22254
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Programmable controllers with no battery (MELSEC-F)
A battery is used for backing up program memory and latched device data and maintaining clock operation in the event of a power failure. The FX3S/FX3G/FX3G... More Details >>
- No:22259
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
All input COM terminals send the same signal because all the terminals are internally connected. To turn on the input, the extension unit must be connected ... More Details >>
- No:22274
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Changing to the monitor write mode automatically changes the online change setting in Options to "Write during RUN (while PLC is running)".With returning to ... More Details >>
- No:22541
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
This occurs when the specified memory does not have consecutive free space in it. In this case, delete unnecessary files or arrange the PLC memory. Select ... More Details >>
- No:22604
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:03
- Category: MELSEC-Q Series
-
The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) An intelligent function module is assigned as a... More Details >>
- No:22725
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:02
- Category: MELSEC-L Series
-
NTP support by the SNTP function of LCPU with built-in Ethernet port
NTP and SNTP are compatible. Therefore, an NTP server can be used for clock setting. More Details >>
- No:22744
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Terminating resistors for CC-Link communication
There are two types of terminating resistors for CC-Link communication. Both two types are packaged with a CC-Link master/local module. (1) 110 ohm, 1/2W (B... More Details >>
- No:22963
- Release Date:2018/09/03 17:31
- Update:2018/09/26 14:47
- Category: Network related products