Acceleration/deceleration time change
Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>
- No:23569
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
Yes, they are included.In addition, a battery (Q6BAT) is also included. More Details >>
- No:23576
- Release Date:2018/09/14 15:09
- Category: Q17nDCPU
-
In order for the programmable controller to receive input pulses completely, the ON duration and OFF duration of inputs in the programmable controller requir... More Details >>
- No:24704
- Release Date:2019/02/27 09:00
- Category: MELSEC-F Series , Main Unit , High-Speed Counting
-
24+ terminal connection of an extension block
For AC power supply type, connect the 24+ terminal of an extension block to the 24+ terminal of a main unit. For DC power supply type, connect the 24+ termi... More Details >>
- No:24786
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Types of Batteries used in MELSEC-F
F2-40BL: Lithium thionyl chloride primary battery FX2NC-32BL: Lithium thionyl chloride primary battery FX3U-32BL: Manganese dioxide lithium primary battery F... More Details >>
- No:22265
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
How to use the database function of the MELSEC iQ-R series
The database function manages tabular data including product information and production information as a database in a programmable controller. <... More Details >>
- No:22476
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:44
- Category: MELSEC iQ-R Series
-
Security key authentication function of MELSEC iQ-R series
The security key authentication function registers a security key in a program file and prevents unauthorized execution or access to the program.You can set... More Details >>
- No:22480
- Release Date:2018/09/03 17:28
- Update:2018/09/19 15:38
- Category: MELSEC iQ-R Series
-
How to display local comments in GX Works2
In the "Reference/Reflection Target for Device Comment" window, switch the "Specify the Reference/Reflection" from "Global" to "Local". More Details >>
- No:22630
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Measurement of the counter in the MC (master control) circuit
When the count condition of the counter in the MC circuit remains set, the counter counts when the MC circuit is turned on. More Details >>
- No:24910
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Main Unit
-
The setting in Latch (1) can be cleared by latch clear operation. The setting in Latch (2) cannot be cleared by latch clear operation. More Details >>
- No:22567
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:48
- Category: MELSEC-Q Series