FAQ
FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Communications using the built-in USB port of the FX3 series
When you connect the built-in USB port of the FX3 series to the personal computer for the first time, you need to install the USB driver into the personal co... More Details >>
- No:22273
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit , Network/Communication
-
I/O assignment of PLC parameters with GX Works3
"PC Parameter" in GX Works2 is "Parameter" in GX Works3. You can set the I/O assignment from "Module Configuration" or "System Parameter". <Setting fr... More Details >>
- No:22475
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:42
- Category: MELSEC iQ-R Series
-
GX Developer's compatibility with 64-bit Windows 7
GX Developer Version 8.98C or later supports 64-bit Windows 7. To install GX Developer to a Windows 7-based personal computer, refer to the following techni... More Details >>
- No:22501
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:19
- Category: MELSEC-Q Series
-
Inputting device comments in GX Works2
Select [Tool] -> [Options] -> [Program Editor] -> "Ladder/SFC"-> "Comment" and change "Reference/Reflection Target for Device Comment" from "Glob... More Details >>
- No:22559
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
NTP support by the SNTP function of LCPU with built-in Ethernet port
NTP and SNTP are compatible. Therefore, an NTP server can be used for clock setting. More Details >>
- No:22744
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
The LCPU error code 4116 is displayed when a built-in I/O instruction that is disabled in the parameter setting is executed. Check for the parameter settings... More Details >>
- No:22807
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
File export of ladder programs
(1) If only GX Developer is used - The operation cannot be carried out for ladder programs. - For device comments, copy and paste operations can be carri... More Details >>
- No:22840
- Release Date:2018/09/03 17:30
- Update:2018/09/22 13:22
- Category: Engineering Software
-
Resistor value for CC-Link cables
The value depends on the type of cable in use. - Ver.1.10-compatible CC-Link dedicated cables: 110 ohm, 1/2W - CC-Link dedicated cables (Version 1.00): 110... More Details >>
- No:22983
- Release Date:2018/09/03 17:31
- Update:2018/10/03 14:42
- Category: Network related products
-
It depends on the servo error.Some can be cleared by "[Cd.5] Axis error reset" but the other cannot unless the servo amplifier's power is turned OFF.Refer to... More Details >>
-
Alarm E7 (Controller forced stop warning) occurs when an forced stop is executed by the Positioning module or the Simple Motion module. The following shows h... More Details >>