FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Power supply of the FX3U-ENET-ADP Ethernet communication special adapter
No, it is not necessary because power is supplied internally from the main unit. More Details >>
- No:24921
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Network/Communication
-
Ver2.00 or later is applicable. (GX Works2 with Ver. 1.87R or later is applicable.) The version of main units can be checked with the last three digits of t... More Details >>
- No:24922
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Main Unit
-
AnyWire-compatible master block of the FX programmable controller
The master block model is FX3U-128BTY-M. The FX3U-128BTY-M is compatible with the AnyWire Bitty series. More Details >>
- No:24923
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Network/Communication
-
Operation speed change during a positioning operation of the FX3U-1PG
Yes, it is possible. Write a new value to the operation speed change value (BFM#56, #55) during the positioning operation. * After the operation speed chang... More Details >>
- No:24927
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Positioning Control
-
Gratis warranty term of the FX programmable controllers
The longest gratis warranty term after manufacturing shall be eighteen (18) months. For details, refer to the gratis warranty term explained in the applicabl... More Details >>
- No:24928
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
Number of files that can be created inside a CF card in the FX3U-CF-ADP
Up to 63 files can be handled simultaneously. In addition, up to 1000 files can be created by creating FIFO function files. * The total capacity of the files... More Details >>
- No:24944
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series , Main Unit , I/O Extension , Accessories
-
Output numbers of the FX programmable controllers
Since they are octal, the number after Y7 is Y10 and after Y77 is Y100. More Details >>
- No:24946
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
- Category: Main Unit
-
The main units with Ver.2.00 or later can read and write programs of the FX3 series connected to the intelligent device station and can monitor devices. (GX... More Details >>
- No:24950
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
181-190 of Total 976