FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
By using the Time calculation FB library, you can perform calculations that across years, months and days. In the time calculation FB library, you can add an... More Details >>
- No:44362
- Release Date:2024/03/27 16:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Meanings of the sink input/source input
The sink input connects to a negative common for 24 V DC. The source input connects to a positive common. The sink input is generally used in Japan and No... More Details >>
- No:22254
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
External power supply for input(MELSEC-F)
For the MELSEC-F series, only DC power supply type can use an external power supply. More Details >>
- No:22268
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit
-
Regarding the range of latch devices
The latch range can be set arbitrarily by the customer. The settings can be found in the memory/device settings of CPU parameters. To back up the link regist... More Details >>
- No:22297
- Release Date:2018/08/30 13:55
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding changing the current value of the high-speed counter.
To rewrite the current value, arbitrary values can be written using the DHCMOV instruction. (Example) Set the current value of the high-speed counter ch1 ... More Details >>
- No:22303
- Release Date:2018/08/30 13:55
- Update:2023/02/06 17:05
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
As the parameter settings of the FX3 intelligent function modules are not supported by GX Works3, they cannot be selected from the element selection window.... More Details >>
- No:22304
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:29
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
You can use the MELSEC iQ-R series inter-module synchronization function together with the CC-Link IE Field Network synchronous communication function.With ... More Details >>
- No:22462
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:51
- Category: MELSEC iQ-R Series
-
Models of extended SRAM cassettes that can be used with MELSEC iQ-R series CPU modules
You can use "NZ2MC-1MBS", "NZ2MC-2MBS", "NZ2MC-4MBS", "NZ2MC-8MBS", "NZ2MC-16MBS",and "NZ2MC-8MBSE". You cannot use extended SRAM cassettes for the high-spe... More Details >>
- No:22468
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:36
- Category: MELSEC iQ-R Series
231-240 of Total 976