  • Torque limit value change

    The torque limit value can be changed regardless of JOG operation status.Set the new torque limit value with "[Cd.22] New torque value". More Details >>

    • No:23608
    • Release Date:2018/09/14 15:09
    • Category: QD75M
  • MELSOFT MT Works2

    MELSOFT MT Works2 is engineering software for Motion controllers that provides comprehensive support - from system design, parameter settings, program creati... More Details >>

  • Home position address

    Set "[Pr.45] Home position address" of the basic parameters for home position return • Axis 1 to 16: 72+150n, 73+150n • Axis 17 to 32: 1000072+150n, 1000073+... More Details >>

    • No:23600
    • Release Date:2018/09/14 15:09
    • Category: RD77MS  ,  RD77GF
  • Acceleration/deceleration time change

    Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>

  • Speed change during operation

    Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program/Motion program Speed change requ... More Details >>

    • No:23572
    • Release Date:2018/09/14 15:09
    • Category: Q17nHCPU  ,  Q17nCPUN
  • Battery holder unit

    Yes, they are included.In addition, a battery (Q6BAT) is also included. More Details >>

    • No:23576
    • Release Date:2018/09/14 15:09
    • Category: Q17nDCPU
  • Deceleration stop

    Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>

    • No:23551
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • Major error 093CH

    Major error 093CH occurs when the absolute position is erased.Execute the home position return after checking the batteries of the Motion CPU module and the ... More Details >>

    • No:23562
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • Speed change during operation

    Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program Speed change request CHGV, CHGVS... More Details >>

  • Warning 093CH

    Warning 093CH (Home position return data incorrect) occurs when the backup data for absolute position restoration is lost.Execute the machine home position r... More Details >>