  • Minor error 197AH

    Minor error 197AH (Home position return zero not passed) occurs in the following case:"[St.1066] zero pass" is OFF when the re-movement to the home position ... More Details >>

    • No:23560
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • MELSOFT MT Works2

    MELSOFT MT Works2 is engineering software for Motion controllers that provides comprehensive support - from system design, parameter settings, program creati... More Details >>

  • Battery holder unit

    Yes, they are included.In addition, a battery (Q6BAT) is also included. More Details >>

    • No:23576
    • Release Date:2018/09/14 15:09
    • Category: Q17nDCPU
  • Major error 093CH

    Major error 093CH occurs when the absolute position is erased.Execute the home position return after checking the batteries of the Motion CPU module and the ... More Details >>

    • No:23562
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • Speed change during operation

    Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program/Motion program Speed change requ... More Details >>

    • No:23573
    • Release Date:2018/09/14 15:09
    • Category: Q17nDCPU  ,  Q170MCPU
  • CUP type of stand-alone Motion controller

    The following shows the specification for the PLC CPU area. Q170MSCPU: Equivalent to PLC CPU "Q03UDCPU" • Program capacity: 30k steps • LD instruction proces... More Details >>

  • Acceleration/deceleration time change

    Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>

    • No:23569
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • Speed change during operation

    Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program Speed change request CHGV,CHGVS ... More Details >>

    • No:23575
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • Torque limit

    Torque is limited by the lower set value of "[Pr.17] Torque limit setting value" and "[Cd.22] New torque value".When the current torque reaches the limit, "b... More Details >>

    • No:23592
    • Release Date:2018/09/14 15:09
    • Category: QD75M
  • Home position address

    Set "[Pr.45] Home position address" of the basic parameters for home position return • Axis 1 to 16: 72+150n, 73+150n • Axis 17 to 32: 1000072+150n, 1000073+... More Details >>

    • No:23600
    • Release Date:2018/09/14 15:09
    • Category: RD77MS  ,  RD77GF