FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
Comparison result of the CMP instruction
A comparison result is held even after the command input turns off. The remaining comparison result can be cleared by using the RST or ZRST instruction. More Details >>
- No:24692
- Release Date:2019/02/27 08:56
- Category: MELSEC-F Series
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Index modifier of the bit device in the FX3GC series
FX3GC series does not support the index modifier for the bit devices. FX3U/FX3UC series supports it. More Details >>
- No:25002
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Number of extension cables that can be used per system
One extension cable can be used per system. Two or more extension cables cannot be used. More Details >>
- No:24958
- Release Date:2019/04/18 14:33
- Category: MELSEC-F Series
-
Output numbers of the FX programmable controllers
Since they are octal, the number after Y7 is Y10 and after Y77 is Y100. More Details >>
- No:24946
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series
-
The FX3U-ENET-L does not support the DHCP function. Set the fixed IP address using FX Configurator-EN-L. (FX Configurator-EN-L can be downloaded from Mitsubi... More Details >>
- No:24869
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series
-
Setting of the FX3U-ENET-ADP Ethernet communication special adapter
GX Works2 with Ver. 1.90U or later can be used for the setting of the FX3U-ENET-ADP. More Details >>
- No:24875
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Network/Communication
-
MC protocol supported by the FX3U-ENET-L
The frame typesupported byMC protocol is equivalent to A-compatible 1E frame. More Details >>
- No:24702
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Network/Communication
-
Number of GOTs (GOT1000 series) that can be connected to a FX3U-ENET-L
Up to two GOTs can be connected toa FX3U-ENET-L and MELSOFT connection needs to be set. More Details >>
- No:24933
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Network/Communication
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
1-10 of Total 198