Output numbers of the FX programmable controllers
Since they are octal, the number after Y7 is Y10 and after Y77 is Y100. More Details >>
- No:24946
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series
-
Index modifier of the bit device in the FX3GC series
FX3GC series does not support the index modifier for the bit devices. FX3U/FX3UC series supports it. More Details >>
- No:25002
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
The FX3U-ENET-L does not support the DHCP function. Set the fixed IP address using FX Configurator-EN-L. (FX Configurator-EN-L can be downloaded from Mitsubi... More Details >>
- No:24869
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series
-
It is not possible to extend the length of the extension cable to over 65cm. Place the main unit separately by using the parallel link or N:N Network functio... More Details >>
- No:24941
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Accessories
-
Using special blocks (extension blocks) away from a main unit
To use the special blocks away from the main unit, connect them with the FX0N-30EC/FX0N-65EC extension cable and the FX2N-CNV-BC connector conversion adapter. More Details >>
- No:24966
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Accessories
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Main Unit
-
MELSOFT connection of the FX3U-ENET-L Ethernet interface block
Up to 2 connections can be opened. More Details >>
- No:24919
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Network/Communication
-
Using a fixed latched (battery backed) type device as a general type device
Clear the required area with the ZRST instruction by using the initial pulse when the programmable controller is set to RUN. To clear all the latched type de... More Details >>
- No:24925
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
Measurement of the counter in the MC (master control) circuit
When the count condition of the counter in the MC circuit remains set, the counter counts when the MC circuit is turned on. More Details >>
- No:24910
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Main Unit
-
Whether the positioning parameter is used or the extension positioning parameter is used can be selected in BFM#32 (positioning parameter selection). Select ... More Details >>
- No:24917
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Positioning Control