Data that can be stored in a memory cassette (FX3U/FX3UC)
The device memory data cannot be stored in a memory cassette. In the FX3U/FX3UC series, a part of device memory data can be latched using a battery. The de... More Details >>
- No:24789
- Release Date:2019/02/28 09:07
- Category: MELSEC-F Series , Accessories
-
Number of occupied points of special function devices
Each special function unit/block has 8 occupied points, except for some special function devices. These 8 points do not occupy 8 points of the actual I/O n... More Details >>
- No:24873
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Main Unit
-
MELSEC-F series high-speed counter blocks that can import differential pulses
The FX2N-1HC, FX2NC-1HC, FX3U-4HSX-ADP, and FX3U-2HC can import differential pulses. More Details >>
- No:24874
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , High-Speed Counting
-
Latched (battery backed) area in the data register (D) of the FX3G/FX3GC series
D128 to D1099 are the latched device area. D1100 to D7999 can be changed to latched (battery backed) type devices by installing an optional battery and setti... More Details >>
- No:24901
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Main Unit
-
The main units with Ver.2.00 or later can read and write programs of the FX3 series connected to the intelligent device station and can monitor devices. (GX... More Details >>
- No:24950
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Connection of the FX3G series and the FX3U-ENET-ADP
AnFX3G-CNV-ADP is required. * When the FX3U-ENET-ADP is used with other special adapters, connect the FX3U-ENET-ADP at the last stage (left end). More Details >>
- No:24951
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Connecting a DC power supply type extension unit to an AC power supply type main unit
No, they cannot be connected. Connect the units having the same power supply type. More Details >>
- No:25008
- Release Date:2019/04/23 11:12
- Category: MELSEC-F Series , Main Unit
-
The FX3U-ENET-ADP does not support the DHCP function. Set the fixed IP address using the parameter setting of GX Works2. On GX Works2, select "Parameter" and... More Details >>
- No:24870
- Release Date:2019/04/15 08:05
- Category: MELSEC-F Series , Network/Communication