Yes, there is. T256 to T319 can be used for the1 ms timer, and T246 to T249 can be used for the 1 ms retentive timer. More Details >>
- No:24680
- Release Date:2019/02/22 11:39
- Update:2019/02/22 14:03
- Category: MELSEC-F Series , Main Unit
-
How to wire the 24V DC power supply for sensors
Connect the "0V (-)" terminal of the external 24V DC power supply to the "COM" terminal (- side of the built-in power supply), one of the input terminals of ... More Details >>
- No:22281
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit
-
How to use variable analog potentiometers in FX3S
Numerical value data 0 to 255 corresponding tothe scale position is stored in the special data register. You can create the analog timer (volume type) by sp... More Details >>
- No:22279
- Release Date:2018/08/30 13:48
- Update:2019/02/14 10:05
- Category: MELSEC-F Series , Main Unit , Analog Control
-
How to ground programmable controllers
For your safety, programmable controllers must be grounded. Incomplete common grounding within the control panel or common grounding with heavy electrical s... More Details >>
- No:22276
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Number of FX3U-16CCL-M CC-Link master blocks that can be connected to the FX3U series
One FX3U-16CCL-M can be connected to the FX3U series. More Details >>
- No:25009
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Network/Communication
-
The main units with Ver.3.10 or later can read and write programs of the FX3 series connected to the intelligent device station and can monitor devices. (GX ... More Details >>
- No:24990
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Instruction execution complete flag
When a flag contact is not programmed directly under the instruction to be checked, the flag may be turned off depending on the execution status of another i... More Details >>
- No:24988
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Main Unit
-
Model of the cable provided with the FX2N series extension unit
The model of the cable isFX0N-5EC. More Details >>
- No:24968
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
- Category: Main Unit