Settings for the FX3U-ENET-ADP
GX Works2 with Ver. 1.87R or later is required. More Details >>
- No:24781
- Release Date:2019/02/27 16:10
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Using a specified bit (on/off) of a word device (D) as a condition for a contact
In the FX3U/FX3UC series, a bit in a word device can be specified. It can be specified by "Word device (D only) + Decimal point + Bit position (0 to F)". A... More Details >>
- No:22261
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22263
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
All input COM terminals send the same signal because all the terminals are internally connected. To turn on the input, the extension unit must be connected ... More Details >>
- No:22274
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
How to check the version of the MELSEC-F series
To check the version of the MELSEC-F series, connect GX Works2 (personal computer) or HPP to a programmable controller, and monitor the data in D8001. The l... More Details >>
- No:24772
- Release Date:2019/02/27 15:22
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
To establish communications between the programmable controller and GX Developer, clear the communication setting. (The communication setting register value ... More Details >>
- No:24876
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Number of GOTs (GOT1000 series) that can be connected to a FX3U-ENET-L
Up to two GOTs can be connected toa FX3U-ENET-L and MELSOFT connection needs to be set. More Details >>
- No:24933
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Network/Communication
-
Changing the time of a programmable controller by using the clock data write instruction (TWR)
When changing the time by using the clock data write instruction (TWR), the control of M8015 (Clock stop/adjustment) is not required. * When the clock data... More Details >>
- No:22266
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit