FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
Connecting special adapters to the FX3G series
An FX3G-CNV-ADP is required. More Details >>
- No:24977
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Assignment of direction signals during positioning
Any number can be assigned. More Details >>
- No:24975
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Positioning Control
-
Yes, it is possible. To set the programmable controller to RUN again, while the programmable controller is stopped, set the built-in RUN/STOP switch as follo... More Details >>
- No:24965
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Main Unit
-
Number of FX3U-64CCL interface blocks that can be added to a main unit
One FX3U-64CCL can be added. More Details >>
- No:24962
- Release Date:2019/04/23 07:17
- Category: MELSEC-F Series , Network/Communication
-
Using the VPN (Virtual Private Network)*1 connection service enables the communications. VPN is a technology that connects networks by encrypting the commun... More Details >>
- No:24908
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Network/Communication
-
Input filter adjustment when a high-speed counter or the interrupt function is used
When a coil of the high-speed counter or an interrupt pointer is programmed, the programmable controller system adjusts the filter constant of the correspond... More Details >>
- No:24867
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , High-Speed Counter
-
Clock function accuracy of the MELSEC-F series
The accuracy is within ±45 seconds/month (ambient temperature: 25ºC). More Details >>
- No:24778
- Release Date:2019/02/27 15:57
- Category: MELSEC-F Series , Main Unit
-
Models of the MELSEC-F series main units
"E" represents AC power supply and "D" represents DC power supply. The alphabets following "E" and "D" represent output types. "S" represents replay output... More Details >>
- No:24776
- Release Date:2019/02/27 15:35
- Category: MELSEC-F Series , Main Unit
-
Comparison result of the CMP instruction
A comparison result is held even after the command input turns off. The remaining comparison result can be cleared by using the RST or ZRST instruction. More Details >>
- No:24692
- Release Date:2019/02/27 08:56
- Category: MELSEC-F Series
-
Battery consumption while the programmable controller is powered on
A battery is consumed regardless of the on/off state ofthe programmable controller. Refer to the User's Manual (Hardware Edition) for the module used, and r... More Details >>
- No:24687
- Release Date:2019/02/22 11:44
- Update:2019/02/22 15:22
- Category: MELSEC-F Series , Main Unit , Accessories
131-140 of Total 198