Terminal layout on the output side of the FX3U-16MR/ES
Yes, they are independent common terminals. More Details >>
- No:24955
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Main Unit
-
Drive products (servo amplifiers) that can be connected to the FX3U-1PG pulse output block
Servo amplifiers, such as MR-J4-□A and MR-JN-□A, that support pulse train input can be connected. For connectable drive products, such as servo amplifiers, ... More Details >>
- No:24940
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
Current value of the battery voltage in the FX3U/FX3UC series
The current value of the battery voltage is stored in the special data register D8005 (battery voltage). More Details >>
- No:24942
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Main Unit
-
Using the VPN (Virtual Private Network)*1 connection service enables the communications. VPN is a technology that connects networks by encrypting the commun... More Details >>
- No:24908
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Network/Communication
-
Connecting special adapters to the FX3G series
An FX3G-CNV-ADP is required. More Details >>
- No:24977
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Switching network between 10BASE-T and 100BASE-TX of the FX3U-ENET-L
It cannot be freely switched. It is automatically switched according to the auto detection function. More Details >>
- No:24964
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Network/Communication
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Target address change during the positioning operation in the FX3U-1PG
Yes, it is possible. Set a new value for the target address to the target address change value (BFM#54, #53) during the positioning operation. * The targ... More Details >>
- No:24986
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Number of FX3U-1PG pulse output blocks that can be connected to the FX3U/FX3UC main unit
For the FX3U series, up to eight FX3U-1PGs can be connected. For the FX3UC series, up to six FX3U-1PGs can be connected. * To connect the FX3U-1PG to the... More Details >>
- No:24973
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
Necessity of a battery when a memory cassette is used
A battery is not required when a memory cassette is used. This is because the sequence programsstored in the memory cassette, exceptfor RAM memory cassette, ... More Details >>