FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
Changing the JOG speed in the FX3U-20SSC-H
Since the JOG speed is the positioning parameter, turn off and on the positioning parameter enable command (X-axis: BFM#519.b4, Y-axis: BFM#619.b4) to enable... More Details >>
- No:24987
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Connection of FX-20P and FX3U series
Whenan entry code (2nd entry code) registration is set in the FX3U series, sucherror canoccur. More Details >>
- No:24983
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Accessories
-
Connecting special adapters to the FX3G series
An FX3G-CNV-ADP is required. More Details >>
- No:24977
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Number of extension cables that can be used per system
One extension cable can be used per system. Two or more extension cables cannot be used. More Details >>
- No:24958
- Release Date:2019/04/18 14:33
- Category: MELSEC-F Series
-
Connection of expansion boards and a memory cassette to the FX3G series main unit
They can be used together. * 14/24-point type FX3G series main unit ・ An expansion board can be connected to BD1 (1st position) and a memory cassette can b... More Details >>
- No:24952
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit
-
File format that can be saved to a CF card in the FX3U-CF-ADP
CSV file can be saved. More Details >>
- No:24938
- Release Date:2019/04/18 14:24
- Category: MELSEC-F Series , Main Unit , Accessories
-
Using the VPN (Virtual Private Network)*1 connection service enables the communications. VPN is a technology that connects networks by encrypting the commun... More Details >>
- No:24908
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Network/Communication
-
Input filter adjustment when a high-speed counter or the interrupt function is used
When a coil of the high-speed counter or an interrupt pointer is programmed, the programmable controller system adjusts the filter constant of the correspond... More Details >>
- No:24867
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , High-Speed Counter
-
Number of remote device stations that can be connected to FX2N-16CCL-M
Eight stations can be connected. More Details >>
- No:24984
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Network/Communication
-
The slave stations cannot be assigned to X/Y numbers. Use the auxiliary relay M. More Details >>
- No:24982
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Network/Communication
141-150 of Total 198