FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
For output terminals of a programmable controller, one common terminal is used for 1, 2, 4, or 8 output points. Each common line is assigned with a different... More Details >>
- No:24780
- Release Date:2019/02/27 15:58
- Category: MELSEC-F Series , Main Unit
-
Replacement of the fuse in the FX programmable controller
Customers cannot replace the fuse. For the replacement, please consult your local Mitsubishi representative. More Details >>
- No:24909
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Main Unit
-
Using a fixed latched (battery backed) type device as a general type device
Clear the required area with the ZRST instruction by using the initial pulse when the programmable controller is set to RUN. To clear all the latched type de... More Details >>
- No:24925
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
Current value of the battery voltage in the FX3U/FX3UC series
The current value of the battery voltage is stored in the special data register D8005 (battery voltage). More Details >>
- No:24942
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Main Unit
-
Setting for installing a memory cassette
When the programmable controller is powered on after a memory cassette is installed, the memory cassette is automatically recognized. After the memory casset... More Details >>
- No:24974
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Turning on a bit in the data register
In the FX3U/FX3UC series, the bit specification of the data register is possible. (Example) D0.7→7th bit in D0 For the other types of MELSEC-F programmable... More Details >>
- No:22275
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Maximum number of characters in a comment that can be transferred to a FX3U series
As project data, up to 32 one-byte characters (16 two-byte characters) can be input to each global device comment. However, the maximum number of characters ... More Details >>
- No:24700
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
The FX3U-ENET-L does not support the DHCP function. Set the fixed IP address using FX Configurator-EN-L. (FX Configurator-EN-L can be downloaded from Mitsubi... More Details >>
- No:24869
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series
-
Program transfer between a handy programming panel (HPP) and a personal computer
The FX-30P can be used to transfer the programs of the FX3 series. More Details >>
- No:24924
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Accessories
151-160 of Total 198