Program transfer between a handy programming panel (HPP) and a personal computer
The FX-30P can be used to transfer the programs of the FX3 series. More Details >>
- No:24924
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Accessories
-
MELSOFT connection of the FX3U-ENET-ADP Ethernet communication special adapter
Up to 4 connections can be opened. More Details >>
- No:24903
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Network/Communication
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
FX series with a built-in USB port
The FX3S,FX3G/FX3GC series hasa built-in USB port. More Details >>
- No:24937
- Release Date:2019/04/18 14:24
- Update:2023/01/31 11:59
- Category: MELSEC-F Series , Main Unit
-
The FX2N-16CCL-M cannot be set as the master station in the parameter setting. Use the FROM/TO instructions and setin the program. More Details >>
- No:25001
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Network/Communication
-
Operation error of the instruction that handles the present value of a high-speed counter
The present value register of the high-speed counter is the 32-bit register. The applied instruction handling the 32-bit register must be the 32-bit instruct... More Details >>
- No:24907
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , High-Speed Counting
-
Positioning blocks/module that can be connected with a manual pulse generator
The FX3U-20SSC-H (differential line driver), FX2N-10PG (differential line driver or open collector: only 5 V type), and FX2N-10GM/FX2N-20GM (open collector) ... More Details >>
- No:24886
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Positioning Control
-
The power supply lamp of a running programmable controller suddenly turned off or flashes
Check whether the lamp is back to normalafter disconnecting the wiring of the "24V" (service power supply) terminal. Ifthe lamp is back to normal,the servic... More Details >>
- No:22267
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:53
- Category: MELSEC-F Series , Main Unit
-
Remote maintenance can be performed by writing a program to a memory cassette and sending the program or by using a personal computer (GX Developer). With a ... More Details >>
- No:24998
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Main Unit
-
Yes, it is possible. To set the programmable controller to RUN again, while the programmable controller is stopped, set the built-in RUN/STOP switch as follo... More Details >>
- No:24965
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Main Unit