MC protocol supported by the FX3U-ENET-L
The frame typesupported byMC protocol is equivalent to A-compatible 1E frame. More Details >>
How to use variable analog potentiome...
Numerical value data 0 to 255 corresponding tothe scale position is stored in the special data register. You can create the analog timer (volume type) by sp... More Details >>
How to reset M8004 (Error occurrence)
Yes, it is. However, if the error cause is not eliminated, M8004 will turn on again after powering on. * How to check the error In the FX3S/FX3G/FX3GC/FX... More Details >>
Certificate of non-applicability to e...
For issuance of a certificate, please consult your local Mitsubishi representative. More Details >>
Parameter setting of the FX3U-16CCL-M
The parameters can be set by using network parameters of GX Works2 (Ver1.73B or later). (FX3U/3UC: Ver3.10 or later) More Details >>
Latch (backup) areas in the auxiliary...
M384 to M1535 and D128 to D1099 can be latched. M1536 to M7679, D1100 to D7999, and R0 to R23999 can be used as latch areas by installing an optional batt... More Details >>
How to install a battery to FX3G/FX3G...
The FX3U-32BL can be installed to the FX3G/FX3GC series. After installation, select [Battery Mode: Use the battery] on the FX parameter window of GX Develop... More Details >>
FX3U-ENET-ADP connectable programmabl...
The FX3U-ENET-ADP can be connected to the FX3G/FX3GC series (both Ver. 2.00 or later) and the FX3U/3UC series (both Ver. 3.10 or later). Products which are ... More Details >>
Keyword protection of the MELSEC-F se...
The keyword protection cannot be forcibly reset. Since only the keyword that has been registered by theuser is acceptable, please take measures to ensure th... More Details >>
Turning on/off a specified bit of a w...
In the FX programmable controllers (FX3U/FX3UC series), a bit in a word device can be specified in a program. It can be specified as "word device (D only) + ... More Details >>