- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
Pulse output type of the FX3U-1PG pulse output block
It is transistor output. Transistor output specifications are as follows. ・ Rated load voltage 5 to 24 V DC ・ Maximum load current 20 mA or lower More Details >>
- No:24972
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
Using the FX3U-16CCL-M and FX2N-16CCL-M together
No, they cannot be added together. Only one FX3U-16CCL-M can be connected to one main unit. Multiple FX2N-16CCL-Ms can be connected to one main unit (dependi... More Details >>
- No:24954
- Release Date:2019/04/18 14:28
- Category: MELSEC-F Series , Network/Communication
-
Positioning blocks/module that can be connected with a manual pulse generator
The FX3U-20SSC-H (differential line driver), FX2N-10PG (differential line driver or open collector: only 5 V type), and FX2N-10GM/FX2N-20GM (open collector) ... More Details >>
- No:24886
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Positioning Control
-
External appearance of the F2-40BL
Some of the F2-40BL batteries installed to a programmable controller are mounted on the printed circuit board. The separately available F2-40BL batteries (sp... More Details >>
- No:24771
- Release Date:2019/02/27 15:17
- Category: MELSEC-F Series , Accessories
-
Setting of the FX3U-ENET-ADP Ethernet communication special adapter
GX Works2 with Ver. 1.90U or later can be used for the setting of the FX3U-ENET-ADP. More Details >>
- No:24875
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Network/Communication
-
MC protocol supported by the FX3U-ENET-L
The frame typesupported byMC protocol is equivalent to A-compatible 1E frame. More Details >>
- No:24702
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Network/Communication
-
Modules that support differential line driver outputs
The FX3U-2HSY-ADP, FX2N-10PG support differential line driver outputs. More Details >>
- No:24691
- Release Date:2019/02/27 08:56
- Update:2023/02/15 13:09
- Category: MELSEC-F Series , Positioning Control
-
Operation of the first special function unit/block in the FX3UC series
Usually, unit number of the first special function unit/block is "K0". However, when the main unit is FX3UC-32MT-LT(-LT2), the unit number "K0" is assigned t... More Details >>
- No:24995
- Release Date:2019/04/23 10:40
- Category: MELSEC-F Series , Main Unit
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
- Category: Main Unit
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control