FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
Analog input modules that can be used in the FX3G series
The FX3G-2AD-BD (2-channel analog input expansion board), FX3U-4AD-ADP (4-channel analog input special adapter), and FX3U-3A-ADP (2-channel analog input/1-ch... More Details >>
- No:24960
- Release Date:2019/04/23 07:17
- Category: MELSEC-F Series , Analog Control
-
Using special blocks (extension blocks) away from a main unit
To use the special blocks away from the main unit, connect them with the FX0N-30EC/FX0N-65EC extension cable and the FX2N-CNV-BC connector conversion adapter. More Details >>
- No:24966
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Accessories
-
Connection of the FX3G series and the GT1020/GT1030 series (5 V type)
Only one GT1020/GT1030 series (5 V type) can be connected to the FX3G series. To connect two GOTs, select the GT1020/GT1030 series (24 V type). More Details >>
- No:24969
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
- Category: Main Unit
-
Pulse output system of the FX3U-1PG pulse output block
Forward (FP) and reverse (RP) pulse or pulse (PLS) with direction (DIR) can be selected. More Details >>
- No:24957
- Release Date:2019/04/18 14:28
- Category: MELSEC-F Series , Positioning Control
-
Operation of the first special function unit/block in the FX3UC series
Usually, unit number of the first special function unit/block is "K0". However, when the main unit is FX3UC-32MT-LT(-LT2), the unit number "K0" is assigned t... More Details >>
- No:24995
- Release Date:2019/04/23 10:40
- Category: MELSEC-F Series , Main Unit
-
Positioning blocks/module that can be connected with a manual pulse generator
The FX3U-20SSC-H (differential line driver), FX2N-10PG (differential line driver or open collector: only 5 V type), and FX2N-10GM/FX2N-20GM (open collector) ... More Details >>
- No:24886
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Positioning Control
-
MELSOFT connection of the FX3U-ENET-ADP Ethernet communication special adapter
Up to 4 connections can be opened. More Details >>
- No:24903
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Network/Communication
-
Using the FX3U-16CCL-M and FX2N-16CCL-M together
No, they cannot be added together. Only one FX3U-16CCL-M can be connected to one main unit. Multiple FX2N-16CCL-Ms can be connected to one main unit (dependi... More Details >>
- No:24954
- Release Date:2019/04/18 14:28
- Category: MELSEC-F Series , Network/Communication
11-20 of Total 198