Number of FX3U-1PG pulse output blocks that can be connected to the FX3U/FX3UC main unit
For the FX3U series, up to eight FX3U-1PGs can be connected. For the FX3UC series, up to six FX3U-1PGs can be connected. * To connect the FX3U-1PG to the... More Details >>
- No:24973
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
Assignment of direction signals during positioning
Any number can be assigned. More Details >>
- No:24975
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Positioning Control
-
Triac output type main units in the FX3 series
The FX3U-32MS/ES and FX3U-64MS/ES are triac output type. More Details >>
- No:24980
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Main Unit
-
Changing the JOG speed in the FX3U-20SSC-H
Since the JOG speed is the positioning parameter, turn off and on the positioning parameter enable command (X-axis: BFM#519.b4, Y-axis: BFM#619.b4) to enable... More Details >>
- No:24987
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Reflecting the changes in the communication setting
Power off and on the programmable controller again after the communication setting is changed. More Details >>
- No:25006
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Number of FX3U-16CCL-M CC-Link master blocks that can be connected to the FX3U series
One FX3U-16CCL-M can be connected to the FX3U series. More Details >>
- No:25009
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Network/Communication
-
For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22272
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Connecting local stations to the FX3U-16CCL-M
No, local stations cannot be connected to the FX3U-16CCL-M. Remote I/O stations, remote device stations, and intelligent device stations can be connected to... More Details >>
- No:24791
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Network/Communication
21-30 of Total 198