FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
Ver.3.10 or later is applicable. (GX Works2 with Ver.1.73B or later is applicable.) The version of the main unit can be checked with the last three digits of... More Details >>
- No:24918
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Main Unit
-
Using the FX3U-ENET-ADP and the RS-232C/RS-485 together (FX3U/FX3UC series)
Up to two of the following optional communication equipment, including the FX3U-ENET-ADP (for Ethernet communications), can be used for the FX3U/FX3UC series... More Details >>
- No:24686
- Release Date:2019/02/22 11:40
- Update:2019/02/22 15:16
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Turning on/off a specified bit of a word device (D) using a simple program
In the FX programmable controllers (FX3U/FX3UC series), a bit in a word device can be specified in a program. It can be specified as "word device (D only) + ... More Details >>
- No:25011
- Release Date:2019/04/23 11:13
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Programming software and tool for the FX2N-10GM/FX2N-20GM
Use the "FX-PCS-VPS/WIN" software for personal computer or the "E-20TP-SET0" handy programming panel. More Details >>
- No:25014
- Release Date:2019/04/23 11:16
- Category: MELSEC-F Series , Engineering Software , Accessories
-
Maximum number of characters in a comment that can be transferred to a FX3U series
As project data, up to 32 one-byte characters (16 two-byte characters) can be input to each global device comment. However, the maximum number of characters ... More Details >>
- No:24700
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Special auxiliary relay which is always on (MELSEC-F)
M8000 More Details >>
- No:22258
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Communication setting methods when the FX3U-232-BD is used
The non-protocol communication can be set by the following two methods: (1) setting parameters using a programming tool, such as GX Works2, or (2) writing da... More Details >>
- No:24773
- Release Date:2019/02/27 15:24
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Differences between the file register and other registers
The file register is used for storing predetermined values (such as specification values for product inspection). Other registers are used as a temporary st... More Details >>
- No:22256
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
To establish communications between the programmable controller and GX Developer, clear the communication setting. (The communication setting register value ... More Details >>
- No:24876
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
21-30 of Total 198