Number of remote device stations that can be connected to FX2N-16CCL-M
Eight stations can be connected. More Details >>
- No:24984
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Network/Communication
-
Target address change during the positioning operation in the FX3U-1PG
Yes, it is possible. Set a new value for the target address to the target address change value (BFM#54, #53) during the positioning operation. * The targ... More Details >>
- No:24986
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Operation of the first special function unit/block in the FX3UC series
Usually, unit number of the first special function unit/block is "K0". However, when the main unit is FX3UC-32MT-LT(-LT2), the unit number "K0" is assigned t... More Details >>
- No:24995
- Release Date:2019/04/23 10:40
- Category: MELSEC-F Series , Main Unit
-
Remote maintenance can be performed by writing a program to a memory cassette and sending the program or by using a personal computer (GX Developer). With a ... More Details >>
- No:24998
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Main Unit
-
FX series products that support CC-Link Ver.2.0
FX3U-16CCL-M CC-Link master block and the FX3U-64CCL CC-Link interface block supports CC-Link Ver.2.0. Both blocks are dedicated for the FX3 series. More Details >>
- No:25004
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Network/Communication
-
Terminal blocks for the MELSEC-F series
Whether the terminal block is removable or not differs depending on the series. Types of the terminal blocks for the MELSEC-F series main units are as follow... More Details >>
- No:24774
- Release Date:2019/02/27 15:34
- Category: MELSEC-F Series , Main Unit
-
Models of the MELSEC-F series main units
"E" represents AC power supply and "D" represents DC power supply. The alphabets following "E" and "D" represent output types. "S" represents replay output... More Details >>
- No:24776
- Release Date:2019/02/27 15:35
- Category: MELSEC-F Series , Main Unit
-
Setting day of the week when using the TWR instruction (FX3 series)
Day of week is automatically set. When data written to the data register for storing day-of-the-week data is within the setting range (K = 0 to 6), the day ... More Details >>
- No:24777
- Release Date:2019/02/27 15:57
- Category: MELSEC-F Series , Main Unit
-
Number of occupied points of special function devices
Each special function unit/block has 8 occupied points, except for some special function devices. These 8 points do not occupy 8 points of the actual I/O n... More Details >>
- No:24873
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Main Unit
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Main Unit