FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
Using special blocks (extension blocks) away from a main unit
To use the special blocks away from the main unit, connect them with the FX0N-30EC/FX0N-65EC extension cable and the FX2N-CNV-BC connector conversion adapter. More Details >>
- No:24966
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Accessories
-
Number of FX3U-1PG pulse output blocks that can be connected to the FX3U/FX3UC main unit
For the FX3U series, up to eight FX3U-1PGs can be connected. For the FX3UC series, up to six FX3U-1PGs can be connected. * To connect the FX3U-1PG to the... More Details >>
- No:24973
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
Analog output modules that can be used in the FX3G series
The FX3G-1DA-BD (1-channel analog output extension board), FX3U-4DA-ADP (4-channel analog output special adapter), and FX3U-3A-ADP (2-channel analog input/1-... More Details >>
- No:24979
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Analog Control
-
Protection components of relay contacts
We recommend you to connecta diode for commutation to the DC load, and surge absorber (C-R) to the AC load for the protection of the relay contacts. More Details >>
- No:24999
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Main Unit
-
Connecting local stations to the FX3U-16CCL-M
No, local stations cannot be connected to the FX3U-16CCL-M. Remote I/O stations, remote device stations, and intelligent device stations can be connected to... More Details >>
- No:24791
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Network/Communication
-
The analog input type (temperature/voltage/current) and offset/gain can be set for each channel. More Details >>
- No:24902
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Analog Control
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
Output frequency of the FX3U-1PG pulse output block
It is from 1 Hz to 200 kHz. More Details >>
- No:24981
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Positioning Control
-
CC-Link version of FX2N-16CCL-M
The CC-Link version ofFX2N-16CCL-M is Ver.1.10. More Details >>
- No:24992
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Network/Communication
-
Terminal layout of the FX3U-1PG and FX2N-1PG pulse output blocks
Yes, they have the same terminal layout. More Details >>
- No:24900
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Positioning Control
21-30 of Total 198