Terminal layout on the output side of the FX3U-16MR/ES
Yes, they are independent common terminals. More Details >>
- No:24955
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Main Unit
-
Types of the ports built in the FX programmable controllers
There are RS422 × 1ch for the FX1S/FX1N/FX1NC/FX2N/FX2NC/FX3U/FX3UC series and RS422 × 1ch and USB × 1ch for the FX3G/FX3GC series. More Details >>
- No:24971
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit
-
Triac output type main units in the FX3 series
The FX3U-32MS/ES and FX3U-64MS/ES are triac output type. More Details >>
- No:24980
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Main Unit
-
Input of the R device of the FX3U series in the FX-20P
Since the FX3U series does not support the FX-20P, available device ranges are within the range of the FX2N. ("R" devices do not exist in the FX2N.) The ha... More Details >>
- No:24989
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Accessories
-
Setting day of the week when using the TWR instruction (FX3 series)
Day of week is automatically set. When data written to the data register for storing day-of-the-week data is within the setting range (K = 0 to 6), the day ... More Details >>
- No:24777
- Release Date:2019/02/27 15:57
- Category: MELSEC-F Series , Main Unit
-
Connecting local stations to the FX3U-16CCL-M
No, local stations cannot be connected to the FX3U-16CCL-M. Remote I/O stations, remote device stations, and intelligent device stations can be connected to... More Details >>
- No:24791
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Network/Communication
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Pulse output system of the FX3U-1PG pulse output block
Forward (FP) and reverse (RP) pulse or pulse (PLS) with direction (DIR) can be selected. More Details >>
- No:24957
- Release Date:2019/04/18 14:28
- Category: MELSEC-F Series , Positioning Control
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Pulse output type of the FX3U-1PG pulse output block
It is transistor output. Transistor output specifications are as follows. ・ Rated load voltage 5 to 24 V DC ・ Maximum load current 20 mA or lower More Details >>
- No:24972
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control