FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series
FAQ
Keyword Search
FAQ within [ MELSEC-F Series ]
-
Latched (battery backed) area in the data register (D) of the FX3G/FX3GC series
D128 to D1099 are the latched device area. D1100 to D7999 can be changed to latched (battery backed) type devices by installing an optional battery and setti... More Details >>
- No:24901
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Main Unit
-
Terminal layout on the output side of the FX3U-16MR/ES
Yes, they are independent common terminals. More Details >>
- No:24955
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Main Unit
-
One FX3U-ENET-ADP can be connected at the last stage (left end) of adapters for the FX3GC series. * The FX3U-ENET-ADP is a communication special adapter and... More Details >>
- No:24967
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Analog output modules that can be used in the FX3G series
The FX3G-1DA-BD (1-channel analog output extension board), FX3U-4DA-ADP (4-channel analog output special adapter), and FX3U-3A-ADP (2-channel analog input/1-... More Details >>
- No:24979
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Analog Control
-
Temperature input modules that can be used with FX3G series
FX3U-4AD-PT-ADP (Pt100 temperature sensor input special adapter), FX3U-4AD-PTW-ADP (Pt100 temperature sensor input special adapter), and FX3U-4AD-TC-ADP (K/J... More Details >>
- No:24993
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Analog Control
-
MELSOFT connection of the FX3U-ENET-L Ethernet interface block
Up to 2 connections can be opened. More Details >>
- No:24919
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Network/Communication
-
Current value of the battery voltage in the FX3U/FX3UC series
The current value of the battery voltage is stored in the special data register D8005 (battery voltage). More Details >>
- No:24942
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Main Unit
-
Switching network between 10BASE-T and 100BASE-TX of the FX3U-ENET-L
It cannot be freely switched. It is automatically switched according to the auto detection function. More Details >>
- No:24964
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Network/Communication
-
Input of the R device of the FX3U series in the FX-20P
Since the FX3U series does not support the FX-20P, available device ranges are within the range of the FX2N. ("R" devices do not exist in the FX2N.) The ha... More Details >>
- No:24989
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Accessories
-
FX series with a built-in USB port
The FX3S,FX3G/FX3GC series hasa built-in USB port. More Details >>
- No:24937
- Release Date:2019/04/18 14:24
- Update:2023/01/31 11:59
- Category: MELSEC-F Series , Main Unit
51-60 of Total 198