For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22263
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Programmable controllers with no battery (MELSEC-F)
A battery is used for backing up program memory and latched device data and maintaining clock operation in the event of a power failure. The FX3S/FX3G/FX3G... More Details >>
- No:22259
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Battery replacement during power-on
Replacethe battery when the programmable controller is powered off. For example, forthe FX3U/FX3UC series, data will be held for about 20 seconds after be... More Details >>
- No:22257
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:54
- Category: MELSEC-F Series , Main Unit , Accessories
-
Number of FX3U-16CCL-M CC-Link master blocks that can be added to a main unit
One FX3U-16CCL-M can be added. More Details >>
- No:24994
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Network/Communication
-
Yes, it is possible. To set the programmable controller to RUN again, while the programmable controller is stopped, set the built-in RUN/STOP switch as follo... More Details >>
- No:24965
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Main Unit
-
MELSEC-F series high-speed counter blocks that can import differential pulses
The FX2N-1HC, FX2NC-1HC, FX3U-4HSX-ADP, and FX3U-2HC can import differential pulses. More Details >>
- No:24874
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , High-Speed Counting
-
Settings for the FX3U-ENET-ADP
GX Works2 with Ver. 1.87R or later is required. More Details >>
- No:24781
- Release Date:2019/02/27 16:10
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
The power supply lamp of a running programmable controller suddenly turned off or flashes
Check whether the lamp is back to normalafter disconnecting the wiring of the "24V" (service power supply) terminal. Ifthe lamp is back to normal,the servic... More Details >>
- No:22267
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:53
- Category: MELSEC-F Series , Main Unit
-
Reflecting the changes in the communication setting
Power off and on the programmable controller again after the communication setting is changed. More Details >>
- No:25006
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Accessories of the FX3UC-16MR/DS-T and the FX3UC-16MR/D-T
The "FX2NC-100MPCB" power supply cable for main unit is provided with the FX3UC-16MR/DS-T. The "FX2NC-100MPCB" and the "FX2NC-100BPCB" power supply cable for... More Details >>
- No:25005
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Main Unit , Accessories