For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22272
- Release Date:2018/08/30 13:48
-
Model name of a built-in battery (FX3U/FX3UC)
FX3U-32BL More Details >>
- No:22278
- Release Date:2018/08/30 13:48
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
-
Yes, there is. T256 to T319 can be used for the1 ms timer, and T246 to T249 can be used for the 1 ms retentive timer. More Details >>
- No:24680
- Release Date:2019/02/22 11:39
- Update:2019/02/22 14:03
-
Replacement of the fuse in the FX programmable controller
Customers cannot replace the fuse. For the replacement, please consult your local Mitsubishi representative. More Details >>
- No:24909
- Release Date:2019/04/15 11:30
-
Ver.3.10 or later is applicable. (GX Works2 with Ver.1.73B or later is applicable.) The version of the main unit can be checked with the last three digits of... More Details >>
- No:24918
- Release Date:2019/04/17 11:40
-
Thecomment may not have been written tothe programmable controller. Or, the comment display setting may be required on the GX Works2 side. [Writing a com... More Details >>
- No:24681
- Release Date:2019/02/22 11:40
- Update:2019/02/22 14:15
-
Maximum number of characters in a comment that can be transferred to a FX3U series
As project data, up to 32 one-byte characters (16 two-byte characters) can be input to each global device comment. However, the maximum number of characters ... More Details >>
- No:24700
- Release Date:2019/02/27 08:59
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
-
How to set battery-less operation(FX3U/FX3UC)
To perform battery-less operation in the FX3U/FX3UC series, set parameters using GX Works2(or GX Developer). Please refer to the following manual for furt... More Details >>
- No:22277
- Release Date:2018/08/30 13:48
- Update:2019/02/19 08:47