- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series > Main Unit
FAQ
Keyword Search
FAQ within [ Main Unit ]
-
Differences between the file register and other registers
The file register is used for storing predetermined values (such as specification values for product inspection). Other registers are used as a temporary st... More Details >>
- No:22256
- Release Date:2018/08/30 13:48
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
-
Programmable controllers with no battery (MELSEC-F)
A battery is used for backing up program memory and latched device data and maintaining clock operation in the event of a power failure. The FX3S/FX3G/FX3G... More Details >>
- No:22259
- Release Date:2018/08/30 13:48
-
For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22263
- Release Date:2018/08/30 13:48
-
Maximum number of characters in a comment that can be transferred to a FX3U series
As project data, up to 32 one-byte characters (16 two-byte characters) can be input to each global device comment. However, the maximum number of characters ... More Details >>
- No:24700
- Release Date:2019/02/27 08:59
-
When a personal computer (GX Works2) is connected to the RS-232C port of a programmable controller, communications between the personal computer and the prog... More Details >>
- No:24782
- Release Date:2019/02/27 16:10
-
Changing the time of a programmable controller by using the clock data write instruction (TWR)
When changing the time by using the clock data write instruction (TWR), the control of M8015 (Clock stop/adjustment) is not required. * When the clock data... More Details >>
- No:22266
- Release Date:2018/08/30 13:48
-
Types of data backup methods (FX3G series)
1. Data backup using an optional battery Built-in RAM data and clock data of a programmable controller are held by using an optional battery. The life of... More Details >>
- No:24701
- Release Date:2019/02/27 08:59
-
Necessity for installing a noise filter
Unless the necessity is described in manuals, a noise filter is not required. However, if the programmable controller is used in an environment with much no... More Details >>
- No:22283
- Release Date:2018/08/30 13:48
-
How to check the version of the MELSEC-F series
To check the version of the MELSEC-F series, connect GX Works2 (personal computer) or HPP to a programmable controller, and monitor the data in D8001. The l... More Details >>
- No:24772
- Release Date:2019/02/27 15:22