Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
-
Using the FX3U-ENET-ADP and the RS-232C/RS-485 together (FX3U/FX3UC series)
Up to two of the following optional communication equipment, including the FX3U-ENET-ADP (for Ethernet communications), can be used for the FX3U/FX3UC series... More Details >>
- No:24686
- Release Date:2019/02/22 11:40
- Update:2019/02/22 15:16
-
Setting for installing a memory cassette
When the programmable controller is powered on after a memory cassette is installed, the memory cassette is automatically recognized. After the memory casset... More Details >>
- No:24974
- Release Date:2019/04/23 07:20
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
-
Terminal blocks for the MELSEC-F series
Whether the terminal block is removable or not differs depending on the series. Types of the terminal blocks for the MELSEC-F series main units are as follow... More Details >>
- No:24774
- Release Date:2019/02/27 15:34
-
Connection of the FX3G series and the FX3U-ENET-ADP
AnFX3G-CNV-ADP is required. * When the FX3U-ENET-ADP is used with other special adapters, connect the FX3U-ENET-ADP at the last stage (left end). More Details >>
- No:24951
- Release Date:2019/04/18 14:27
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
-
Setting day of the week when using the TWR instruction (FX3 series)
Day of week is automatically set. When data written to the data register for storing day-of-the-week data is within the setting range (K = 0 to 6), the day ... More Details >>
- No:24777
- Release Date:2019/02/27 15:57
-
24+ terminal connection of an extension block
For AC power supply type, connect the 24+ terminal of an extension block to the 24+ terminal of a main unit. For DC power supply type, connect the 24+ termi... More Details >>
- No:24786
- Release Date:2019/02/28 09:06
-
Protection components of relay contacts
We recommend you to connecta diode for commutation to the DC load, and surge absorber (C-R) to the AC load for the protection of the relay contacts. More Details >>
- No:24999
- Release Date:2019/04/23 10:39