- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series > Main Unit
FAQ
Keyword Search
FAQ within [ Main Unit ]
-
Model of the cable provided with the FX2N series extension unit
The model of the cable isFX0N-5EC. More Details >>
- No:24968
- Release Date:2019/04/23 07:19
-
One FX3U-ENET-ADP can be connected at the last stage (left end) of adapters for the FX3U series. *The FX3U-ENET-ADP is a communication special adapter and o... More Details >>
- No:24912
- Release Date:2019/04/17 11:39
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
-
Number of occupied points of special function devices
Each special function unit/block has 8 occupied points, except for some special function devices. These 8 points do not occupy 8 points of the actual I/O n... More Details >>
- No:24873
- Release Date:2019/04/15 08:06
-
Setting day of the week when using the TWR instruction (FX3 series)
Day of week is automatically set. When data written to the data register for storing day-of-the-week data is within the setting range (K = 0 to 6), the day ... More Details >>
- No:24777
- Release Date:2019/02/27 15:57
-
Terminal blocks for the MELSEC-F series
Whether the terminal block is removable or not differs depending on the series. Types of the terminal blocks for the MELSEC-F series main units are as follow... More Details >>
- No:24774
- Release Date:2019/02/27 15:34
-
Remote maintenance can be performed by writing a program to a memory cassette and sending the program or by using a personal computer (GX Developer). With a ... More Details >>
- No:24998
- Release Date:2019/04/23 10:38
-
Operation of the first special function unit/block in the FX3UC series
Usually, unit number of the first special function unit/block is "K0". However, when the main unit is FX3UC-32MT-LT(-LT2), the unit number "K0" is assigned t... More Details >>
- No:24995
- Release Date:2019/04/23 10:40
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
-
CF cards that can be used in the FX3U-CF-ADP
The CF cards, whose operations are guaranteed, are the following five models manufactured by Mitsubishi Electric. GT05-MEM-128MC, GT05-MEM-256MC, GT05-MEM-5... More Details >>
- No:24945
- Release Date:2019/04/18 14:26