Using the FX3U-ENET-ADP and the RS-232C/RS-485 together (FX3U/FX3UC series)
Up to two of the following optional communication equipment, including the FX3U-ENET-ADP (for Ethernet communications), can be used for the FX3U/FX3UC series... More Details >>
- No:24686
- Release Date:2019/02/22 11:40
- Update:2019/02/22 15:16
-
Gratis warranty term of the FX programmable controllers
The longest gratis warranty term after manufacturing shall be eighteen (18) months. For details, refer to the gratis warranty term explained in the applicabl... More Details >>
- No:24928
- Release Date:2019/04/17 11:42
-
Setting day of the week when using the TWR instruction (FX3 series)
Day of week is automatically set. When data written to the data register for storing day-of-the-week data is within the setting range (K = 0 to 6), the day ... More Details >>
- No:24777
- Release Date:2019/02/27 15:57
-
Connection of a memory cassette and a display module to the FX3G series main unit
For the 14/24-point type FX3G series main unit, they cannot be connected together. For the 40/60-point type FX3G series main unit, they canbe connected toget... More Details >>
- No:24978
- Release Date:2019/04/23 07:20
-
Using a fixed latched (battery backed) type device as a general type device
Clear the required area with the ZRST instruction by using the initial pulse when the programmable controller is set to RUN. To clear all the latched type de... More Details >>
- No:24925
- Release Date:2019/04/17 11:42
-
Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
-
AC input type main unit in the FX3 series
FX3U-32MR/UA1 and FX3U-64MR/UA1 are AC input types. More Details >>
- No:24991
- Release Date:2019/04/23 10:37
-
FX series with a built-in USB port
The FX3S,FX3G/FX3GC series hasa built-in USB port. More Details >>
- No:24937
- Release Date:2019/04/18 14:24
- Update:2023/01/31 11:59
-
The thickness of wireshould be2 square millimeters or more, andclass D grounding (grounding resistance: 100 Ω or less) should be performed. More Details >>
- No:24899
- Release Date:2019/04/15 11:30