Assignment of direction signals during positioning
Any number can be assigned. More Details >>
- No:24975
- Release Date:2019/04/23 07:20
-
Protection components of relay contacts
We recommend you to connecta diode for commutation to the DC load, and surge absorber (C-R) to the AC load for the protection of the relay contacts. More Details >>
- No:24999
- Release Date:2019/04/23 10:39
-
Accessories of the FX3UC-16MR/DS-T and the FX3UC-16MR/D-T
The "FX2NC-100MPCB" power supply cable for main unit is provided with the FX3UC-16MR/DS-T. The "FX2NC-100MPCB" and the "FX2NC-100BPCB" power supply cable for... More Details >>
- No:25005
- Release Date:2019/04/23 11:11
-
For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22263
- Release Date:2018/08/30 13:48
-
External power supply for input(MELSEC-F)
For the MELSEC-F series, only DC power supply type can use an external power supply. More Details >>
- No:22268
- Release Date:2018/08/30 13:48
-
Externally switching the operating status of a programmable controller
On the Project view of the Navigation window, select "Parameter" → "PLC Parameter" using GX Works2 (or GX Developer). Click the "PLC System(1)" tab, and set ... More Details >>
- No:24768
- Release Date:2019/02/27 15:01
-
Terminal blocks for the MELSEC-F series
Whether the terminal block is removable or not differs depending on the series. Types of the terminal blocks for the MELSEC-F series main units are as follow... More Details >>
- No:24774
- Release Date:2019/02/27 15:34
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
-
Latched (battery backed) area in the data register (D) of the FX3G/FX3GC series
D128 to D1099 are the latched device area. D1100 to D7999 can be changed to latched (battery backed) type devices by installing an optional battery and setti... More Details >>
- No:24901
- Release Date:2019/04/15 11:31