How to ground programmable controllers
For your safety, programmable controllers must be grounded. Incomplete common grounding within the control panel or common grounding with heavy electrical s... More Details >>
- No:22276
- Release Date:2018/08/30 13:48
-
Models from the FX programmable controllers that support the extended register (R)
The following models from the FX3 series support the extended register (R). FX3U/FX3UC series: R0-R32767, FX3G series: R0-R23999 More Details >>
- No:24904
- Release Date:2019/04/15 11:31
-
Connection of a memory cassette and a display module to the FX3G series main unit
For the 14/24-point type FX3G series main unit, they cannot be connected together. For the 40/60-point type FX3G series main unit, they canbe connected toget... More Details >>
- No:24978
- Release Date:2019/04/23 07:20
-
Transferring/editing programs in the previous FX programmable controllers using GX Works2
The earlier series of the FX programmable controllers are compatible with the latest series of the FX programmable controllers. More Details >>
- No:25012
- Release Date:2019/04/23 11:16
-
Differences between the FX3UC-32MT-LT and the FX3UC-32MT-LT2
The built-in CC-Link/LT setting differs. For the FX3UC-32MT-LT, the built-in CC-Link/LT setting is performed with the DIP switch. For the FX3UC-32MT-LT2, th... More Details >>
- No:24956
- Release Date:2019/04/18 14:28
-
For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22272
- Release Date:2018/08/30 13:48
-
Externally switching the operating status of a programmable controller
On the Project view of the Navigation window, select "Parameter" → "PLC Parameter" using GX Works2 (or GX Developer). Click the "PLC System(1)" tab, and set ... More Details >>
- No:24768
- Release Date:2019/02/27 15:01
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
-
How to set battery-less operation(FX3U/FX3UC)
To perform battery-less operation in the FX3U/FX3UC series, set parameters using GX Works2(or GX Developer). Please refer to the following manual for furt... More Details >>
- No:22277
- Release Date:2018/08/30 13:48
- Update:2019/02/19 08:47
-
Necessity of a battery when a memory cassette is used
A battery is not required when a memory cassette is used. This is because the sequence programsstored in the memory cassette, exceptfor RAM memory cassette, ... More Details >>
- No:24770
- Release Date:2019/02/27 15:00