Necessity of a battery when a memory cassette is used
A battery is not required when a memory cassette is used. This is because the sequence programsstored in the memory cassette, exceptfor RAM memory cassette, ... More Details >>
- No:24770
- Release Date:2019/02/27 15:00
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
24+ terminal connection of an extension block
For AC power supply type, connect the 24+ terminal of an extension block to the 24+ terminal of a main unit. For DC power supply type, connect the 24+ termi... More Details >>
- No:24786
- Release Date:2019/02/28 09:06
-
The thickness of wireshould be2 square millimeters or more, andclass D grounding (grounding resistance: 100 Ω or less) should be performed. More Details >>
- No:24899
- Release Date:2019/04/15 11:30
-
Using an expansion board and a special adapter together
In the FX1S/FX1N/FX2N series, only the expansion board for special adapter connection can be used together with the special adapter. In the FX3G series (onl... More Details >>
- No:24906
- Release Date:2019/04/15 11:32
-
Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
-
Using a fixed latched (battery backed) type device as a general type device
Clear the required area with the ZRST instruction by using the initial pulse when the programmable controller is set to RUN. To clear all the latched type de... More Details >>
- No:24925
- Release Date:2019/04/17 11:42
-
One FX3U-ENET-ADP can be connected at the last stage (left end) of adapters for the FX3UC series. *The FX3U-ENET-ADP is a communication special adapter and ... More Details >>
- No:24932
- Release Date:2019/04/23 07:21
-
Data collection with FX programmable controller
Data stored in the programmable controller can be saved to a CF card usinga FX3U-CF-ADP CF card special adapter for the FX3U/FX3UC series. More Details >>
- No:24936
- Release Date:2019/04/18 14:24