- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-F Series > Main Unit
FAQ
Keyword Search
FAQ within [ Main Unit ]
-
Battery consumption while the programmable controller is powered on
A battery is consumed regardless of the on/off state ofthe programmable controller. Refer to the User's Manual (Hardware Edition) for the module used, and r... More Details >>
- No:24687
- Release Date:2019/02/22 11:44
- Update:2019/02/22 15:22
-
Latched (battery backed) area in the data register (D) of the FX3G/FX3GC series
D128 to D1099 are the latched device area. D1100 to D7999 can be changed to latched (battery backed) type devices by installing an optional battery and setti... More Details >>
- No:24901
- Release Date:2019/04/15 11:31
-
Cable provided with the FX2N series extension unit
It is available as a repair part. Please consult with localMitsubishi Electric representative. More Details >>
- No:24916
- Release Date:2019/04/17 11:40
-
Remote maintenance can be performed by writing a program to a memory cassette and sending the program or by using a personal computer (GX Developer). With a ... More Details >>
- No:24998
- Release Date:2019/04/23 10:38
-
Accessories of the FX3UC-16MR/DS-T and the FX3UC-16MR/D-T
The "FX2NC-100MPCB" power supply cable for main unit is provided with the FX3UC-16MR/DS-T. The "FX2NC-100MPCB" and the "FX2NC-100BPCB" power supply cable for... More Details >>
- No:25005
- Release Date:2019/04/23 11:11
-
The power supply lamp of a running programmable controller suddenly turned off or flashes
Check whether the lamp is back to normalafter disconnecting the wiring of the "24V" (service power supply) terminal. Ifthe lamp is back to normal,the servic... More Details >>
- No:22267
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:53
-
Power supply cable of the input extension blocks for the connector type programmable controllers
Forthe first input extension block connecting to a main unit, use the FX2NC-100BPCB power supply cable provided with the main unit, and supply power from a 2... More Details >>
- No:24911
- Release Date:2019/04/15 11:32
-
Ver.3.10 or later is applicable. (GX Works2 with Ver.1.73B or later is applicable.) The version of the main unit can be checked with the last three digits of... More Details >>
- No:24918
- Release Date:2019/04/17 11:40
-
For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22263
- Release Date:2018/08/30 13:48
-
Models from the FX programmable controllers that support the extended register (R)
The following models from the FX3 series support the extended register (R). FX3U/FX3UC series: R0-R32767, FX3G series: R0-R23999 More Details >>
- No:24904
- Release Date:2019/04/15 11:31