Connection of the FX3G series and the FX3U-ENET-ADP
AnFX3G-CNV-ADP is required. * When the FX3U-ENET-ADP is used with other special adapters, connect the FX3U-ENET-ADP at the last stage (left end). More Details >>
- No:24951
- Release Date:2019/04/18 14:27
-
Types of Batteries used in MELSEC-F
F2-40BL: Lithium thionyl chloride primary battery FX2NC-32BL: Lithium thionyl chloride primary battery FX3U-32BL: Manganese dioxide lithium primary battery F... More Details >>
- No:22265
- Release Date:2018/08/30 13:48
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
-
Model of the cable provided with the FX2N series extension unit
The model of the cable isFX0N-5EC. More Details >>
- No:24968
- Release Date:2019/04/23 07:19
-
For output terminals of a programmable controller, one common terminal is used for 1, 2, 4, or 8 output points. Each common line is assigned with a different... More Details >>
- No:24780
- Release Date:2019/02/27 15:58
-
To establish communications between the programmable controller and GX Developer, clear the communication setting. (The communication setting register value ... More Details >>
- No:24876
- Release Date:2019/04/15 08:07
-
Certificate of non-applicability to export MELSEC-F to other countries
For issuance of a certificate, please consult your local Mitsubishi representative. More Details >>
- No:22264
- Release Date:2018/08/30 13:48
-
Turning on a bit in the data register
In the FX3U/FX3UC series, the bit specification of the data register is possible. (Example) D0.7→7th bit in D0 For the other types of MELSEC-F programmable... More Details >>
- No:22275
- Release Date:2018/08/30 13:48
-
How to ground programmable controllers
For your safety, programmable controllers must be grounded. Incomplete common grounding within the control panel or common grounding with heavy electrical s... More Details >>
- No:22276
- Release Date:2018/08/30 13:48