Externally switching the operating status of a programmable controller
On the Project view of the Navigation window, select "Parameter" → "PLC Parameter" using GX Works2 (or GX Developer). Click the "PLC System(1)" tab, and set ... More Details >>
- No:24768
- Release Date:2019/02/27 15:01
-
Repair term for the FX programmable controllers after discontinuation of production
Mitsubishi Electric shall accept product repairs for seven years after production of the product is discontinued. However, some products cannot be repaired d... More Details >>
- No:24996
- Release Date:2019/04/23 10:41
-
All input COM terminals send the same signal because all the terminals are internally connected. To turn on the input, the extension unit must be connected ... More Details >>
- No:22274
- Release Date:2018/08/30 13:48
-
To establish communications between the programmable controller and GX Developer, clear the communication setting. (The communication setting register value ... More Details >>
- No:24876
- Release Date:2019/04/15 08:07
-
Differences between the FX3UC-32MT-LT and the FX3UC-32MT-LT2
The built-in CC-Link/LT setting differs. For the FX3UC-32MT-LT, the built-in CC-Link/LT setting is performed with the DIP switch. For the FX3UC-32MT-LT2, th... More Details >>
- No:24956
- Release Date:2019/04/18 14:28
-
Operation processing time of the programmable controller
The constant operation processing time can be achieved by using constant scan mode. Refer to the programming manual of the programmable controller used. More Details >>
- No:24997
- Release Date:2019/04/23 10:38
-
Differences between the file register and other registers
The file register is used for storing predetermined values (such as specification values for product inspection). Other registers are used as a temporary st... More Details >>
- No:22256
- Release Date:2018/08/30 13:48
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
-
Built-in variable analog potentiometers of the FX3G series
D8030 for VR1, and D8031 for VR2. More Details >>
- No:24769
- Release Date:2019/02/27 15:01
-
Measurement of the counter in the MC (master control) circuit
When the count condition of the counter in the MC circuit remains set, the counter counts when the MC circuit is turned on. More Details >>
- No:24910
- Release Date:2019/04/15 11:32