Connection of the FX3G series and the GT1020/GT1030 series (5 V type)
Only one GT1020/GT1030 series (5 V type) can be connected to the FX3G series. To connect two GOTs, select the GT1020/GT1030 series (24 V type). More Details >>
- No:24969
- Release Date:2019/04/23 07:19
-
Connection of a memory cassette and a display module to the FX3G series main unit
For the 14/24-point type FX3G series main unit, they cannot be connected together. For the 40/60-point type FX3G series main unit, they canbe connected toget... More Details >>
- No:24978
- Release Date:2019/04/23 07:20
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
-
Current value of the battery voltage in the FX3U/FX3UC series
The current value of the battery voltage is stored in the special data register D8005 (battery voltage). More Details >>
- No:24942
- Release Date:2019/04/18 14:25
-
Connection of expansion boards and a memory cassette to the FX3G series main unit
They can be used together. * 14/24-point type FX3G series main unit ・ An expansion board can be connected to BD1 (1st position) and a memory cassette can b... More Details >>
- No:24952
- Release Date:2019/04/18 14:27
-
Extension blocks and units that can be used in the FX3U series
The operation is not guaranteed. Please select the extension blocks and units from FX2N series. More Details >>
- No:24935
- Release Date:2019/04/18 14:24
-
Using the inverter communication instruction in FX3G series
It can be used in the FX3G series main units with Ver. 1.10 or later. More Details >>
- No:24961
- Release Date:2019/04/23 07:17
-
FX series with a built-in USB port
The FX3S,FX3G/FX3GC series hasa built-in USB port. More Details >>
- No:24937
- Release Date:2019/04/18 14:24
- Update:2023/01/31 11:59
-
Measurement of the counter in the MC (master control) circuit
When the count condition of the counter in the MC circuit remains set, the counter counts when the MC circuit is turned on. More Details >>
- No:24910
- Release Date:2019/04/15 11:32
-
Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39