The main units with Ver.2.00 or later can read and write programs of the FX3 series connected to the intelligent device station and can monitor devices. (GX... More Details >>
- No:24950
- Release Date:2019/04/18 14:27
-
Repair term for the FX programmable controllers after discontinuation of production
Mitsubishi Electric shall accept product repairs for seven years after production of the product is discontinued. However, some products cannot be repaired d... More Details >>
- No:24996
- Release Date:2019/04/23 10:41
-
Ethernet-connectable modules in MELSEC-F
The FX3U-ENET-L and FX3U-ENET-ADP are Ethernet-connectable. The FX3U-ENET-L can be used with the FX3U and FX3UC series (both Ver. 2.21 or later). The FX3U-... More Details >>
- No:22270
- Release Date:2018/08/30 13:48
-
Assignment of remote input device and remote output device of FX3U-16CCL-M
The remote input device and the remote output device cannot be assigned in network parameters. To assign them, create a program for updating data. For de... More Details >>
- No:24792
- Release Date:2019/02/28 09:08
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
-
Necessity for installing a noise filter
Unless the necessity is described in manuals, a noise filter is not required. However, if the programmable controller is used in an environment with much no... More Details >>
- No:22283
- Release Date:2018/08/30 13:48
-
Differences between the FX3UC-32MT-LT and the FX3UC-32MT-LT2
The built-in CC-Link/LT setting differs. For the FX3UC-32MT-LT, the built-in CC-Link/LT setting is performed with the DIP switch. For the FX3UC-32MT-LT2, th... More Details >>
- No:24956
- Release Date:2019/04/18 14:28
-
Connecting the FX3U-ENET-L whose parameters have not been set
When writing parameters first time, write the parameters for Ethernet (data of FX Configurator-RN-L) from a personal computer to a programmable controller ma... More Details >>
- No:24790
- Release Date:2019/02/28 09:08
-
Communication setting methods when the FX3U-232-BD is used
The non-protocol communication can be set by the following two methods: (1) setting parameters using a programming tool, such as GX Works2, or (2) writing da... More Details >>
- No:24773
- Release Date:2019/02/27 15:24
-
The FX2N-16CCL-M cannot be set as the master station in the parameter setting. Use the FROM/TO instructions and setin the program. More Details >>
- No:25001
- Release Date:2019/04/23 10:39