FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
The inverter (FR-A520-5.5K) itself generates approximately 310 W of heat. This is the amount generated under the inverter rated current 100% load. Since the ... More Details >>
- No:21523
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
What functions are added compared with FR-A200?
The following functions are added or improved: - Auto tuning function- Fast-response current limit operation is improved.- Characteristics of magnetic flux v... More Details >>
- No:21638
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
We offer the following: <<Dedicated motor model variation>>- With standard legs (SF-VR__)5.5 kW, 7.5 kW, 11 kW, 15 kW, 18.5 kW, 22 kW, 30 kW, 37 ... More Details >>
- No:21649
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
The motor-generated torque elements have the following relationship:Torque T = K I V/FK: ConstantI: CurrentV: VoltageF: FrequencyThe inverter regularly perfo... More Details >>
- No:21952
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Single-phase power supply drive
For a single-phase 200 V power supply, you can use the FR-E520S series for up to 0.75 kW motor.If you use the three-phase 200 V power supply inverter with a ... More Details >>
- No:22015
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Insulation level of the MM-EFS
F class (155 deg C) More Details >>
- No:20809
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Others
-
It is not supported but can be used. Passive elements such as reactors and brake resistors are out of the scope of the KC (Radio Waves Act (South Korea)). More Details >>
- No:20813
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Frequency setting by the CC-Link
When the frequency setting value is written by the CC-Link to EEPROM, the frequency setting value set with the PU (operation panel) is changed. More Details >>
- No:20851
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
The torque limit setting is defined as an absolute value. Thus, when -100% is written to the torque limit, the torque is limited at 100%. More Details >>
- No:20920
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The value is displayed in 0.1 rpm increments under Vector control. However, the value is rounded down to the first decimal place and displayed in 1 rpm incre... More Details >>
- No:21021
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800