FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
Frequency misalignment at current input
It seems that calibration of the current input is slightly incorrect.By using Pr.904 (Frequency setting current bias) and Pr.905 (Gain), you can calibrate th... More Details >>
- No:22014
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Since the input power factor is improved to approximately 1, the power supply capacity can be reduced to 2/3 to 3/4 of an inverter without a power factor imp... More Details >>
- No:21556
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
The inverter efficiency (power factor) for the inverter alone is approximately 75 to 80%. However, by installing the power factor improving DC reactor to the... More Details >>
- No:21512
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A100
-
Relationship between frequency and load current
If the load is heavy and the output current is higher than the control value, you can adjust Pr.22 (Stall prevention operation level) to trigger the stall pr... More Details >>
- No:21450
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
The signal becomes 0 when the RES signal is turned ON. More Details >>
- No:21238
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The standby power of the FR-F700PJ series (with filterpack) is registered in member's page of Mitsubishi Electric FA Global Website. Refer to the Technical N... More Details >>
- No:21210
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Save the parameter file (.rpm) after reading the system file (.mel) created in SW1. With the saved parameter file (.rpm), the parameter of the 700 series can... More Details >>
- No:21141
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Yes. More Details >>
- No:21038
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Winding diameter calculation is available for all controls (dancer feedback speed control, tension sensor feedback speed control, tension sensorless torque c... More Details >>
- No:20886
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Operation panel extension cable
Yes, you can use the 10BASE-T cable (straight) with the E500. More Details >>
- No:22085
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500