FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
If the command is 0.01 Hz or higher, the positioning control is performed. More Details >>
- No:21001
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes, it is included. More Details >>
- No:20933
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It indicate that the actual number of connectable units differs depending on the master side specification although the maximum number of connectable units o... More Details >>
- No:20839
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
No, you cannot use the safety stop function. More Details >>
- No:20817
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-B
-
Operation at external operation/stop
It is recommended to turn OFF the start signals (STF and STR) when stopping the inverter.In this case, it is not probable that the motor rotates due to a cal... More Details >>
- No:22102
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-E500
-
1. The braking torque can be considered 50% of the motor rated torque.2. The largest stress the DC injection brake gives to the motor is the motor heat gener... More Details >>
- No:22088
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Control wire of FR-HC RDY signal
The contact between the terminals RDY and SE is open collector output.Operation is:Normal: Non-conductiveFault: Conductive More Details >>
- No:22017
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
The FR-AU03 is a dedicated product for the FR-A024. Although it cannot be attached directly to other inverters (FR-A200 and FR-Z, FR-U series), it can be use... More Details >>
- No:21603
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Can I connect it to high power factor converter?
It can be connected to an inverter that supports the high power factor converter FR-HC. (It cannot be connected to conventional inverters.) How to identify i... More Details >>
- No:21602
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Driving German pole change motor by inverter
I cannot tell whether or not you can drive the motor because the electrical specifications are not clear. It is considered that you may drive the pole chang... More Details >>
- No:21518
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
1141-1150 of Total 1306