  • FR-HC2

    Check that not only the current but also the various elements of the fuse such as cut-off speed and life are equivalent to those of the recommended product. More Details >>

  • Wiring length

    Under Real sensorless vector control, the maximum wiring length is 500 m. Under Vector control with encoder, the maximum wiring length is 100 m. More Details >>

  • Instruction manual

    PDF data is available free of charge with free registration from the Mitsubishi Electric FA Global Website. All the printed materials are available for a fee. More Details >>

  • FR-BSF01

    It is not grounded to the enclosure due to the resin coating. More Details >>

  • FR-A800

    Position control is available under vector control with an encoder. Under PM sensorless vector control in combination with a MM-CF motor, simple positioning ... More Details >>

    • No:21105
    • Release Date:2018/08/22 16:25
    • Category: FREQROL-A800
  • Operation panel

    No, it cannot be connected to the RS-485 terminal. The 485 terminal supports the Mitsubishi protocol and Modbus-RTU, but it does not support the PU protocol.... More Details >>

  • FR-A800

    UVT will occur when reactor is not connected. Always connect a reactor that matches the motor capacity. More Details >>

  • FR-A800-CRN

    The anti-sway control can be performed with the inverter alone. More Details >>

  • FR-A800-R2R

    A tension sensor such as a dancer roll is required for speed control. Because an actual line speed input is required for the winding diameter calculation by ... More Details >>

  • FR-A8NC

    The torque limit setting is defined as an absolute value. Thus, when -100% is written to the torque limit, the torque is limited at 100%. More Details >>