Inverters with the components fixed on the circuit board with an adhesive, an countermeasure against the connector failing, or the cables tied (fixed) togeth... More Details >>
- No:20931
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Because the crimp terminal of 3.5 sq is out of JIS standard. The 5.5 sq crimp terminal can also fix the 3.5 sq cable. More Details >>
- No:20852
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
It is 2 to 3 ms, same as the FR-A800. More Details >>
- No:20819
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Which motors can I use with the inverter?
You can use general-purpose three-phase induction motors.You can also use geared motors if the motor itself is an induction motor.Synchronous motors are not ... More Details >>
- No:22081
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Switching from star-delta operation
It is probable that the torque is insufficient because the load characteristics and inverter output characteristics do not match and the output current value... More Details >>
- No:22049
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Fault contact when connecting separate power supply for each control circuit
Since the inverter's fault contact is an NC contact, it does not open unless a fault occurs.Therefore, when the control power supply (and main circuit power ... More Details >>
- No:22035
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Current increase at motor stop
If the current increases when the motor stops under V/F control (at low speed under a light load), the motor is considered to be in the overexcitation state.... More Details >>
- No:21997
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
1. It is OK to open MC on the output side while the inverter is operating.2. It is OK to open the input side in case of emergency stop. More Details >>
- No:21972
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Installation of external thermal
Since the inverter has a built-in motor overheat protective function called "electronic thermal O/L relay", the external thermal is not required. (If you use... More Details >>
- No:21545
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Remote register when instruction code execution request is issued at CC-Link communication
The value "0" is stored. More Details >>
- No:21234
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL