The FR-E7TR does not have the terminal for the SC and it cannot be used with the FR-E700-SC. More Details >>
- No:20865
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
Winding diameter calculation of the FR-A800-R2R
Z phase is not required for the thickness method. More Details >>
- No:20855
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
Because the crimp terminal of 3.5 sq is out of JIS standard. The 5.5 sq crimp terminal can also fix the 3.5 sq cable. More Details >>
- No:20852
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20847
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
Common terminals of control circuit
If you ground the common terminals of the control circuit, it is connected with the inverter's earthing and the inverter's noise may be input to the control ... More Details >>
- No:22037
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Inverter selection when driving multiple motors
When driving multiple motors with a single inverter, determine the inverter capacity in one of the following two methods:1. When driving multiple motors conn... More Details >>
- No:22007
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
AC reactor and line noise filter wiring
Basically, either is OK.Both orders are electrically identical, but "1" is recommended since it is preferable to place the line noise filter close to the inv... More Details >>
- No:21964
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The following is the amount of heat generated for each capacity:0.1K: 14W 0.2K: 20W 0.4K: 32W 0.75K: 50W1.5K: 80W 2.2K: 100W 3.7K: 160W 5.5K: 290W7.5K:... More Details >>
- No:21706
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700
-
FR-E520 operation mode (Pr.79) selection
The FR-E500 manufactured before May 1998 behaved as you mentioned, and the potentiometer becomes unavailable once you set the frequency on the operation pane... More Details >>
- No:21525
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E500
-
Functions available when using inverter on CC-Link
You can use the regular terminal block wire functions during CC-Link operation. Set Pr.338 (Operation command source) and Pr.339 (Speed command source) to e... More Details >>
- No:21393
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500