Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
1. The braking torque can be considered 50% of the motor rated torque.2. The largest stress the DC injection brake gives to the motor is the motor heat gener... More Details >>
- No:22088
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Negative phase of input power supply
The power supplied to the inverter is converted into DC by the converter inside the inverter and then stored in the capacitor. Thus, reversing the phase sequ... More Details >>
- No:22055
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
PHS does not cause the inverter to malfunction.On the contrary, if you use PHS near an inverter or motor, communication over PHS may become noisy or even get... More Details >>
- No:22018
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Input power supply circuit breaker
When using a motor circuit breaker, the rated current of the motor circuit breaker to use must be equal to or higher than the rated current of the circuit br... More Details >>
- No:21979
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Influence on inverter at motor coasts to stop
An induction motor does not act as a power generator unless voltage is applied to it.Therefore, just rotating due to coasting does not affect the inverter. More Details >>
- No:21940
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Although you can connect an analog or digital indicator to the terminal FM, use an analog indicator since the wiring length is long. (The maximum wiring leng... More Details >>
- No:21415
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Countermeasure against the harmful effect on model selection and other devices
Harmful elements that may affect other devices through the input side of the inverter include noise and harmonics. Harmonics can be reduced by inserting the ... More Details >>
- No:21396
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
There is no setting to disable it, but setting a high torque limit level such as 400 % can disable the limit. More Details >>
- No:21217
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Yes, it is. More Details >>
- No:21213
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is possible by using the terminal A to C with the negative logic setting. More Details >>
- No:21203
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL