Circuit type of the FR-D700W/FR-E700W in the harmonics suppression guideline
It is single-phase bridge (smoothing capacitor, double voltage rectification). More Details >>
- No:20864
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
Yes, they can. More Details >>
- No:20856
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
Winding diameter calculation of the FR-A800-R2R
Z phase is not required for the thickness method. More Details >>
- No:20855
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
Because the crimp terminal of 3.5 sq is out of JIS standard. The 5.5 sq crimp terminal can also fix the 3.5 sq cable. More Details >>
- No:20852
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
It is for the HIV cable. More Details >>
- No:20850
- Release Date:2018/08/22 16:24
- Category: Options
-
High speed sampling of FR Configurator2
High speed sampling is not available. Only the normal sampling is available. More Details >>
- No:20848
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20847
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>
- No:20845
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Leakage current of the FR-HAL/FR-HEL
It is less than 1 mA. More Details >>
- No:20844
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
No, it is not. It is released by the inverter reset that releases E.OHT. More Details >>