Operation command terminal switching
It rotates in the forward direction while STF is ON.And then, when STR is turned ON and STF is turned OFF, the inverter decelerates down to 0 Hz within the s... More Details >>
- No:22070
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
It is not supported but can be used. Passive elements such as reactors and brake resistors are out of the scope of the KC (Radio Waves Act (South Korea)). More Details >>
- No:20813
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
No, it isn't. Use the multiple rating (LD, SLD) of the FR-A800. More Details >>
- No:20972
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
The UL94V-0 flammability standard is satisfied. More Details >>
- No:20990
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Setting a smaller value in Pr.1106 (Torque monitor filter) improves the response because the filter time constant for the torque monitoring becomes smaller, ... More Details >>
- No:21045
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
For the FR-F700P, only dedicated IPM motor (MM-EFS, MM-THE4) can be driven. For the FR-F800, the name is different because PM motors manufactured by other co... More Details >>
- No:21061
- Release Date:2018/08/22 16:25
- Category: FREQROL-F800
-
They are not output while the motor is coasting even under Vector control. More Details >>
- No:21158
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
CC-Link monitor and parameter setting
1. Since you can monitor the output frequency independently, you do not need to switch monitoring by the monitor commands. Assign the remote register RWr0 to... More Details >>
- No:21418
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Relationship between undervoltage warning and instantaneous power failure
When an instantaneous power failure occurs and the inverter's bus voltage drops below the standard value, it outputs an undervoltage warning and stops its ou... More Details >>
- No:21974
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-U100
-
Safety stop function of the FR-D700/FR-E700
It is recommended to install the magnetic contactor on the input side of the inverter for safety. The category 3 can be satisfied without installing it. More Details >>
- No:20837
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700